A Novel Interference-Based Supercritical Angle Fluorescence Biosensor

Supercritical angle fluorescence (SAF) is a near-field collection technique used to create surface-sensitive optical transducers. While SAF biosensors require simpler excitation optics compared with total internal reflection fluorescence (TIRF)-based systems, they rely on complex fluorescence collection setups involving large, expensive microscopes to achieve similar sensitivities. In this article, we present a novel interference-based SAF transducer that leverages complementary metal oxide semiconductor (CMOS)-compatible technologies to significantly simplify and miniaturize the collection scheme without compromising sensitivity. The transducer incorporates an interference filter designed to block both excitation light and undercritical angle fluorescence (UAF) while transmitting SAF. We validated its performance using a protein A immunoassay and compared the results to those of the same assay performed on fluorescence well plates. Our SAF transducer achieved a limit of detection (LoD) of 1 pM, compared to 10 pM for the well plates. Furthermore, the transducer enables a washless assay format, significantly reducing the time to result. Its CMOS-compatible materials also support scalable, cost-effective manufacturing by using standard semiconductor fabrication processes.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-21
DOI
https://doi.org/10.1021/acssensors.5c02258
Primary Topic
Near-Field Optical Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Interference-Based Supercritical Angle Fluorescence Biosensor

Tim Steylaerts, Pol Van Dorpe, Finub James Shirley, Pieter Neutens et al.
ACS Sensors
Near-Field Optical Microscopy
article

A Novel Interference-Based Supercritical Angle Fluorescence Biosensor

Tim Steylaerts, Pol Van Dorpe, Finub James Shirley, Pieter Neutens, Ali Amir Saleh, Hans Dusar
article en

Abstract

Supercritical angle fluorescence (SAF) is a near-field collection technique used to create surface-sensitive optical transducers. While SAF biosensors require simpler excitation optics compared with total internal reflection fluorescence (TIRF)-based systems, they rely on complex fluorescence collection setups involving large, expensive microscopes to achieve similar sensitivities. In this article, we present a novel interference-based SAF transducer that leverages complementary metal oxide semiconductor (CMOS)-compatible technologies to significantly simplify and miniaturize the collection scheme without compromising sensitivity. The transducer incorporates an interference filter designed to block both excitation light and undercritical angle fluorescence (UAF) while transmitting SAF. We validated its performance using a protein A immunoassay and compared the results to those of the same assay performed on fluorescence well plates. Our SAF transducer achieved a limit of detection (LoD) of 1 pM, compared to 10 pM for the well plates. Furthermore, the transducer enables a washless assay format, significantly reducing the time to result. Its CMOS-compatible materials also support scalable, cost-effective manufacturing by using standard semiconductor fabrication processes.

ACS SensorsVol. 10(12)
IMEC (BE), KU Leuven (BE)
Openalex Percentile: Top 65%
Near-Field Optical Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.