EasySpiro: Assessing Lung Function via Arbitrary Exhalations on Commodity Earphones

Conventional pulmonary function tests (PFTs) are important but costly. Hence, prior research has proposed IoT sensor-based solutions to facilitate cost-efficient, at-home PFT. However, these solutions require the subject to perform maximal exhalations, a task often challenging without supervision, compromising test accuracy. In response to this challenge, this study introduces EasySpiro that, for the first time, uses non-maximal exhalations to measure PFT indicators. This is challenging since PFT indicators are only defined for maximal exhalations, and there are no guidelines to derive them from submaximal exhalations. To address that, we observe that pulmonary deficiencies affect all types of breathing, where the underlying pulmonary deficiency should be the same under different breathing efforts. Leveraging this insight, we design a reconstruction model to predict the ideal maximal breathing patterns based on submaximal ones and utilize these reconstructions for PFT. Furthermore, since the body dynamics reflect the exhalation effort, we use self-supervised learning techniques to encode body dynamics into breathing effort representations to guide the reconstruction process. We integrate these designs into earphones with microphones to measure breathing patterns and IMUs to measure body dynamics. We collaborate with a hospital and develop a dataset from 50 patients with various diseases to evaluate EasySpiro's performance, which shows an accurate prediction of PFT indicators based on non-maximal exhalations with an error rate of 7%. In addition, we open-source the collected dataset to encourage future research.

Authors

Institutions

Publication Details

Published
2025-11-03
DOI
https://doi.org/10.1145/3680207.3723489
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EasySpiro: Assessing Lung Function via Arbitrary Exhalations on Commodity Earphones

Yanbin Gong, Wentao Xie, Baichen Yang, Yizhen Zhang et al.
1 citations
Non-Invasive Vital Sign Monitoring
0.67
article

EasySpiro: Assessing Lung Function via Arbitrary Exhalations on Commodity Earphones

Yanbin Gong, Wentao Xie, Baichen Yang, Yizhen Zhang, Jin Zhang, Shifang Yang, Wěi Li, Chi Xu, Qian Zhang
article en
1 citations

Abstract

Conventional pulmonary function tests (PFTs) are important but costly. Hence, prior research has proposed IoT sensor-based solutions to facilitate cost-efficient, at-home PFT. However, these solutions require the subject to perform maximal exhalations, a task often challenging without supervision, compromising test accuracy. In response to this challenge, this study introduces EasySpiro that, for the first time, uses non-maximal exhalations to measure PFT indicators. This is challenging since PFT indicators are only defined for maximal exhalations, and there are no guidelines to derive them from submaximal exhalations. To address that, we observe that pulmonary deficiencies affect all types of breathing, where the underlying pulmonary deficiency should be the same under different breathing efforts. Leveraging this insight, we design a reconstruction model to predict the ideal maximal breathing patterns based on submaximal ones and utilize these reconstructions for PFT. Furthermore, since the body dynamics reflect the exhalation effort, we use self-supervised learning techniques to encode body dynamics into breathing effort representations to guide the reconstruction process. We integrate these designs into earphones with microphones to measure breathing patterns and IMUs to measure body dynamics. We collaborate with a hospital and develop a dataset from 50 patients with various diseases to evaluate EasySpiro's performance, which shows an accurate prediction of PFT indicators based on non-maximal exhalations with an error rate of 7%. In addition, we open-source the collected dataset to encourage future research.

Hong Kong University of Science and Technology (HK), Southern University of Science and Technology (CN), Wuhan Union Hospital (CN), Union Hospital (CN), Southern Medical University (CN)
Openalex Percentile: Top 24%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.