Direct Measurement of Photons from the Electron–Hadron Bremsstrahlung at the EIC

Direct detection of bremsstrahlung photons, in principle, offers the most straightforward and most robust method of luminosity determination at the EIC, but requires an extraordinary performance of the photon detector. In this paper, we first discuss the extreme working conditions for such detectors at the EIC and the resulting technology choices. Then, we report on the initial results of Monte Carlo simulations, using <span class="sf">Geant4</span>, of the proposed sampling calorimeter, which is made of a copper absorber with embedded quartz fibres read out by silicon photomultipliers. Finally, the tentative requirements for appropriate readout electronics are formulated. Abstract Published by the Jagiellonian University 2025 authors

Authors

Publication Details

Journal
Acta Physica Polonica B
Published
2025-11-21
DOI
https://doi.org/10.5506/aphyspolb.56.12-a2
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Measurement of Photons from the Electron–Hadron Bremsstrahlung at the EIC

B. Pawlik, K. Piotrzkowski, J. J. Chwastowski, M. Przybycień et al.
Acta Physica Polonica B
Radiation Detection and Scintillator Technologies
article

Direct Measurement of Photons from the Electron–Hadron Bremsstrahlung at the EIC

B. Pawlik, K. Piotrzkowski, J. J. Chwastowski, M. Przybycień, L. Adamczyk, Y. Ali, A. B. Kowalewska
article en

Abstract

Direct detection of bremsstrahlung photons, in principle, offers the most straightforward and most robust method of luminosity determination at the EIC, but requires an extraordinary performance of the photon detector. In this paper, we first discuss the extreme working conditions for such detectors at the EIC and the resulting technology choices. Then, we report on the initial results of Monte Carlo simulations, using <span class="sf">Geant4</span>, of the proposed sampling calorimeter, which is made of a copper absorber with embedded quartz fibres read out by silicon photomultipliers. Finally, the tentative requirements for appropriate readout electronics are formulated. Abstract Published by the Jagiellonian University 2025 authors

Acta Physica Polonica BVol. 56(12)
Openalex Percentile: Top 55%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.