Comparison of Virtual Non-Contrast Images Generated by Spectral Detector Computed Tomography and Conventional Computed Tomography Images of Histologically Confirmed Hepatic Pathologies in 28 Dogs

Spectral detector computed tomography (SDCT) is an innovative imaging technique in veterinary medicine that utilises simultaneous data acquisition at different energy levels using two rows of detectors. This technique provides several interesting applications which improve insights into tissue composition. One implementation is the generation of virtual non-contrast (VNC) images from post-contrast spectral CT data by identifying and subtracting iodine pixels. Preliminary studies suggest that VNC images may offer diagnostic quality comparable to true unenhanced (TUE) images in healthy dogs; however, this technique has yet to be evaluated in clinical patients. This study compared the Hounsfield units (HUs) measured in VNC to those in TUE images of canine hepatic pathologies, taking into account specific types of pathologies based on their imaging characteristics. The attenuation values of the VNC and TUE series were analysed using two one-sided <i>t</i>-tests (TOST), and the signal-to-noise ratio (SNR) was calculated for each region of interest (ROI). A 5-point Likert scale was utilised to assess image noise, quality, and iodine subtraction in the VNC images. A total of 287 ROIs were analysed in the liver, gallbladder, paravertebral muscle, and pancreatic body of 28 dogs with histopathologically confirmed hepatic pathologies. 92.61% of the hepatic ROIs displayed a "negligible" difference of ≤10 HUs between VNC and TUE images, with significant <i>p</i>-values of <0.05 maintained for all ROIs within the limit of ≤10 HUs in the TOST, confirming equivalence between the two imaging modalities. The image quality assessment indicated that SDCT-derived images provided equal or superior quality compared to conventional CT. Therefore, it can be concluded that VNC images calculated from SDCT data could be an alternative to conventional TUE images for hepatic pathologies.

Authors

Institutions

Publication Details

Journal
Animals
Published
2025-11-21
DOI
https://doi.org/10.3390/ani15233366
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Virtual Non-Contrast Images Generated by Spectral Detector Computed Tomography and Conventional Computed Tomography Images of Histologically Confirmed Hepatic Pathologies in 28 Dogs

Sebastian Meller, Philipp Lietz, Verena Nerschbach, Holger A. Volk et al.
Animals
Advanced X-ray and CT Imaging
article

Comparison of Virtual Non-Contrast Images Generated by Spectral Detector Computed Tomography and Conventional Computed Tomography Images of Histologically Confirmed Hepatic Pathologies in 28 Dogs

Sebastian Meller, Philipp Lietz, Verena Nerschbach, Holger A. Volk, Andreas Beineke, Adriano Wang‐Leandro, Kristina Merhof, Alkje M. van Gemmeren, Lydia K. Claußen
article en

Abstract

Spectral detector computed tomography (SDCT) is an innovative imaging technique in veterinary medicine that utilises simultaneous data acquisition at different energy levels using two rows of detectors. This technique provides several interesting applications which improve insights into tissue composition. One implementation is the generation of virtual non-contrast (VNC) images from post-contrast spectral CT data by identifying and subtracting iodine pixels. Preliminary studies suggest that VNC images may offer diagnostic quality comparable to true unenhanced (TUE) images in healthy dogs; however, this technique has yet to be evaluated in clinical patients. This study compared the Hounsfield units (HUs) measured in VNC to those in TUE images of canine hepatic pathologies, taking into account specific types of pathologies based on their imaging characteristics. The attenuation values of the VNC and TUE series were analysed using two one-sided <i>t</i>-tests (TOST), and the signal-to-noise ratio (SNR) was calculated for each region of interest (ROI). A 5-point Likert scale was utilised to assess image noise, quality, and iodine subtraction in the VNC images. A total of 287 ROIs were analysed in the liver, gallbladder, paravertebral muscle, and pancreatic body of 28 dogs with histopathologically confirmed hepatic pathologies. 92.61% of the hepatic ROIs displayed a "negligible" difference of ≤10 HUs between VNC and TUE images, with significant <i>p</i>-values of <0.05 maintained for all ROIs within the limit of ≤10 HUs in the TOST, confirming equivalence between the two imaging modalities. The image quality assessment indicated that SDCT-derived images provided equal or superior quality compared to conventional CT. Therefore, it can be concluded that VNC images calculated from SDCT data could be an alternative to conventional TUE images for hepatic pathologies.

AnimalsVol. 15(23)
University of Veterinary Medicine Hannover, Foundation (DE)
Openalex Percentile: Top 65%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.