An AC voltage sensorless predictive current control method for grid-tied inverter with enhanced robustness against current DC offset

Conventional AC voltage sensorless predictive current control methods for grid-tied inverter are often sensitive to current DC offset errors, resulting in worse control performance. To solve this problem, this paper proposed an improved grid voltage observer as well as a new lumped DC offset observation method. First, the drawbacks of the conventional grid voltage observer are reviewed. Then, based on the backstepping design approach, an improved grid voltage observer is designed, which can remove the influences of the current DC offsets. Third, the effects of the current DC offset on the current control is analyzed, and a new lumped DC offset observation method is designed, which can estimate and compensate the current DC offset well. Fourth, based on the two proposed observers, a new AC voltage sensorless predictive current control method is achieved with enhanced robustness against current DC offset. Finally, experimental studies are carried out, which verify the strong robustness against current DC offsets of the proposed method.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-21
DOI
https://doi.org/10.1038/s41598-025-25183-1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An AC voltage sensorless predictive current control method for grid-tied inverter with enhanced robustness against current DC offset

Guolin Zhang, Lingfeng Meng, Jinyuan Li, Jiqiang Wang et al.
Scientific Reports
Microgrid Control and Optimization
article

An AC voltage sensorless predictive current control method for grid-tied inverter with enhanced robustness against current DC offset

Guolin Zhang, Lingfeng Meng, Jinyuan Li, Jiqiang Wang, Weihao Dong
article en

Abstract

Conventional AC voltage sensorless predictive current control methods for grid-tied inverter are often sensitive to current DC offset errors, resulting in worse control performance. To solve this problem, this paper proposed an improved grid voltage observer as well as a new lumped DC offset observation method. First, the drawbacks of the conventional grid voltage observer are reviewed. Then, based on the backstepping design approach, an improved grid voltage observer is designed, which can remove the influences of the current DC offsets. Third, the effects of the current DC offset on the current control is analyzed, and a new lumped DC offset observation method is designed, which can estimate and compensate the current DC offset well. Fourth, based on the two proposed observers, a new AC voltage sensorless predictive current control method is achieved with enhanced robustness against current DC offset. Finally, experimental studies are carried out, which verify the strong robustness against current DC offsets of the proposed method.

Scientific ReportsVol. 15(1)
J-Power (Japan) (JP), PowerChina (China) (CN), China Guodian Corporation (China) (CN)
Openalex Percentile: Top 55%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.