Power−efficient ramped stimulation in a fully implantable cochlear implant

Cochlear implants (CIs) are among the most established neuromodulation devices, providing auditory perception through electrical stimulation of the auditory nerve. While conventional stimulation strategies rely on symmetric biphasic rectangular pulses, alternative pulse shapes may offer improvements in neural activation and energy efficiency-particularly for fully implantable CI systems where power consumption is a key limitation. In this study, we investigate the efficacy of anodic-first ramped biphasic pulse shapes compared to conventional anodic-first rectangular pulses, using a custom-designed fully implantable cochlear implant (FICI) system in an in vivo guinea pig model. Electrically evoked auditory brainstem responses (eABRs) were recorded in response to four charge-balanced waveform types: Rectangular, RampUp, RampDown, and RampLong. In this single-subject feasibility study, ramped waveforms elicited significantly larger eABR amplitudes, steeper input-output functions, and shorter latencies compared to rectangular pulses. Additionally, we characterized transmission efficiency across the electrode-tissue interface by analyzing waveform spectra and their attenuation through a frequency-dependent medium model. After correcting for these medium-specific losses, in the anodic-first biphasic configuration, RampUp and RampLong pulses demonstrated up to 19-22% improvement in power efficiency relative to rectangular pulses at subthreshold response levels. These findings highlight the potential of ramped stimulation to reduce energy consumption without compromising-and in some cases enhancing-neural activation. Such improvements are especially valuable for fully implantable devices, supporting longer battery life and more sustainable stimulation strategies in next-generation CIs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-21
DOI
https://doi.org/10.1038/s41598-025-25077-2
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power−efficient ramped stimulation in a fully implantable cochlear implant

Hasan Uluşan, Haluk Külah, Mehmet Birol Uğur, Muhammed Berat Yüksel et al.
Scientific Reports
Hearing Loss and Rehabilitation
article

Power−efficient ramped stimulation in a fully implantable cochlear implant

Hasan Uluşan, Haluk Külah, Mehmet Birol Uğur, Muhammed Berat Yüksel, Özlem Topçu, Mert Doğan
article en

Abstract

Cochlear implants (CIs) are among the most established neuromodulation devices, providing auditory perception through electrical stimulation of the auditory nerve. While conventional stimulation strategies rely on symmetric biphasic rectangular pulses, alternative pulse shapes may offer improvements in neural activation and energy efficiency-particularly for fully implantable CI systems where power consumption is a key limitation. In this study, we investigate the efficacy of anodic-first ramped biphasic pulse shapes compared to conventional anodic-first rectangular pulses, using a custom-designed fully implantable cochlear implant (FICI) system in an in vivo guinea pig model. Electrically evoked auditory brainstem responses (eABRs) were recorded in response to four charge-balanced waveform types: Rectangular, RampUp, RampDown, and RampLong. In this single-subject feasibility study, ramped waveforms elicited significantly larger eABR amplitudes, steeper input-output functions, and shorter latencies compared to rectangular pulses. Additionally, we characterized transmission efficiency across the electrode-tissue interface by analyzing waveform spectra and their attenuation through a frequency-dependent medium model. After correcting for these medium-specific losses, in the anodic-first biphasic configuration, RampUp and RampLong pulses demonstrated up to 19-22% improvement in power efficiency relative to rectangular pulses at subthreshold response levels. These findings highlight the potential of ramped stimulation to reduce energy consumption without compromising-and in some cases enhancing-neural activation. Such improvements are especially valuable for fully implantable devices, supporting longer battery life and more sustainable stimulation strategies in next-generation CIs.

Scientific ReportsVol. 15(1)
Ankara University (TR), Gazi University (TR)
European Commission
Openalex Percentile: Top 64%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines