Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study

Cancer remains a leading cause of mortality worldwide. Chemotherapy is effective but can cause febrile neutropenia, deplete neutrophils, and increase infection risk. Although timely fever detection is critical to prevent complications, periodic temperature monitoring has inherent limitations. Wearable devices (WDs) for real-time body temperature (RBT) monitoring are emerging as tools for early fever detection, though their clinical feasibility and usability remain unverified. This study assessed the clinical feasibility of a novel WD by comparing its temperature concordance and fever detection capability against a standard reference in patients with cancer. The RBT system's clinical maturity, including its capacity for early fever detection and monitoring treatment-related changes, was evaluated. Furthermore, satisfaction among clinicians and patients was analyzed in a hospital setting. In this prospective study, patients with hematologic malignancies at high infection risk admitted to the Chonnam National University in Hwasun Hospital, South Korea, were enrolled. Data from 47 patients were analyzed to compare MT100D as WD (SEERS Technology Co., Ltd., South Korea) readings with axillary thermometers. Temperature concordance was evaluated using the intraclass correlation coefficient (ICC), and diagnostic performance was compared with the reference thermometer. The early fever detection performance of the MT100D was analyzed to evaluate the clinical effectiveness of the early response system. Usability was evaluated through a five-point Likert scale survey completed by clinical nurses. The MT100D demonstrated good agreement with the reference thermometer (mean difference: -0.19 ± 0.35 °C; ICC: 0.78). The RBT system achieved sensitivity, specificity, and area under the receiver operating characteristic curve values of 81.50%, 96.32%, and 96.60%, respectively. The early fever detection rate was 77.1%, with the RBT system detecting fever an average of 1.13 ± 1.28 h earlier than the reference. Usability and satisfaction assessments showed high patient satisfaction (mean 4.69 ± 0.5; range 4.57-4.80) and moderate clinician satisfaction (mean 3.63 ± 0.75; range 2.89-4.11). Among patients with cancer, including those at risk of febrile neutropenia, the MT100D demonstrated strong concordance with standard thermometry, enabling early fever detection. The RBT system shows promise for the early identification of neutropenic risk during chemotherapy.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-21
DOI
https://doi.org/10.3390/s25237111
Primary Topic
Thermal Regulation in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study

Yun Kwan Kim, Hoon Kook, YeWon Hong, Sunghoon Jung et al.
Sensors
Thermal Regulation in Medicine
article

Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study

Yun Kwan Kim, Hoon Kook, YeWon Hong, Sunghoon Jung, Sun Jung Lee, Ga‐Young Song, Deok‐Hwan Yang, H. Kim, Hee Jo Baek, Seo-Yeon Ahn, Haeun Jang, Mihee Kim, Cheen Song, W. Ray Kim, Young-Shin Lee, Jae-Sook Ahn, Je‐Jung Lee, Gyung Chul Kim, Hyeoung-Joon Kim
article en

Abstract

Cancer remains a leading cause of mortality worldwide. Chemotherapy is effective but can cause febrile neutropenia, deplete neutrophils, and increase infection risk. Although timely fever detection is critical to prevent complications, periodic temperature monitoring has inherent limitations. Wearable devices (WDs) for real-time body temperature (RBT) monitoring are emerging as tools for early fever detection, though their clinical feasibility and usability remain unverified. This study assessed the clinical feasibility of a novel WD by comparing its temperature concordance and fever detection capability against a standard reference in patients with cancer. The RBT system's clinical maturity, including its capacity for early fever detection and monitoring treatment-related changes, was evaluated. Furthermore, satisfaction among clinicians and patients was analyzed in a hospital setting. In this prospective study, patients with hematologic malignancies at high infection risk admitted to the Chonnam National University in Hwasun Hospital, South Korea, were enrolled. Data from 47 patients were analyzed to compare MT100D as WD (SEERS Technology Co., Ltd., South Korea) readings with axillary thermometers. Temperature concordance was evaluated using the intraclass correlation coefficient (ICC), and diagnostic performance was compared with the reference thermometer. The early fever detection performance of the MT100D was analyzed to evaluate the clinical effectiveness of the early response system. Usability was evaluated through a five-point Likert scale survey completed by clinical nurses. The MT100D demonstrated good agreement with the reference thermometer (mean difference: -0.19 ± 0.35 °C; ICC: 0.78). The RBT system achieved sensitivity, specificity, and area under the receiver operating characteristic curve values of 81.50%, 96.32%, and 96.60%, respectively. The early fever detection rate was 77.1%, with the RBT system detecting fever an average of 1.13 ± 1.28 h earlier than the reference. Usability and satisfaction assessments showed high patient satisfaction (mean 4.69 ± 0.5; range 4.57-4.80) and moderate clinician satisfaction (mean 3.63 ± 0.75; range 2.89-4.11). Among patients with cancer, including those at risk of febrile neutropenia, the MT100D demonstrated strong concordance with standard thermometry, enabling early fever detection. The RBT system shows promise for the early identification of neutropenic risk during chemotherapy.

SensorsVol. 25(23)
Pyeongtaek University (KR), Chonnam National University Hwasun Hospital (KR)
Openalex Percentile: Top 58%
Thermal Regulation in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines