High-sensitivity dynamic detection by tapping-mode nanomechanical sensing using an all-fiber microcantilever probe

In the quest for precise microscale material characterization, the development of high-performance sensors has become a pivotal research area. This study reports what we believe to be the first development of a dynamic microforce sensor that integrates a fiber-optic microcantilever probe operating in tapping-mode atomic force microscopy (AFM). By using femtosecond laser two-photon polymerization (TPP) nanolithography, the microstructure cantilever beam probes are prepared on the fiber end faces. Finite element analysis is performed to determine the dynamic mechanical properties of the optical fiber microcantilever, and the structure is optimized by parametric modeling. The optimized sensor shows a microforce sensitivity of 103 Hz/nm, a quality factor (Q) of 326.98, and a pN-level force detection limit (~17 pN). Owing to the simple structure and parallel probe configuration, the integrated sensor offers is highly promising in applications such as the quantitative analysis of viscoelastic properties of soft materials and biological samples.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-11-12
DOI
https://doi.org/10.1364/ol.580667
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-sensitivity dynamic detection by tapping-mode nanomechanical sensing using an all-fiber microcantilever probe

Chao Liu, Liping Hou, Cangtao Zhou, Shuangchen Ruan et al.
Optics Letters
Mechanical and Optical Resonators
article

High-sensitivity dynamic detection by tapping-mode nanomechanical sensing using an all-fiber microcantilever probe

Chao Liu, Liping Hou, Cangtao Zhou, Shuangchen Ruan, Mengqiang Zou, Changrui Liao, Paul Kim-Ho Chu, Zhe Zhang, Shen Liu, Xiaoyang Guo, Famei Wang
article en

Abstract

In the quest for precise microscale material characterization, the development of high-performance sensors has become a pivotal research area. This study reports what we believe to be the first development of a dynamic microforce sensor that integrates a fiber-optic microcantilever probe operating in tapping-mode atomic force microscopy (AFM). By using femtosecond laser two-photon polymerization (TPP) nanolithography, the microstructure cantilever beam probes are prepared on the fiber end faces. Finite element analysis is performed to determine the dynamic mechanical properties of the optical fiber microcantilever, and the structure is optimized by parametric modeling. The optimized sensor shows a microforce sensitivity of 103 Hz/nm, a quality factor (Q) of 326.98, and a pN-level force detection limit (~17 pN). Owing to the simple structure and parallel probe configuration, the integrated sensor offers is highly promising in applications such as the quantitative analysis of viscoelastic properties of soft materials and biological samples.

Optics LettersVol. 50(23)
Chongqing University of Posts and Telecommunications (CN), City University of Hong Kong (HK), Shenzhen University (CN), Shenzhen Technology University (CN), Northeast Petroleum University (CN)
Openalex Percentile: Top 72%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-sensitivity dynamic detection by tapping-mode nanomechanical sensing using an all-fiber microcantilever probe — Chao Liu, Liping Hou, et al. · Optics Letters (2025) | TGRS Research Map | TGRS