Optically‐Coupled X‐Ray Computed Laminography System for High‐Speed Inspection of Lithium‐Ion Batteries

Conventional X-ray computed tomography systems for microstructure inspection typically employ a geometrically magnified imaging setup, requiring a micro-focus X-ray source to mitigate image blurring caused by a finite focal spot size. However, due to its low output power, the micro-focus X-ray source results in prolonged image acquisition times. This study presents a novel optically-coupled X-ray computed laminography system for high-speed inspection. In the proposed system, a scintillator is placed in contact with an object, effectively minimizing image blurring despite the use of an X-ray source with a large focal spot. Consequently, a high-power X-ray tube can be employed without compromising spatial resolution, leading to a significant reduction in scan time. Modulation transfer function analysis confirms that a spatial resolution of 38 µm is achieved using a high-power (400 W) X-ray tube with a 400 µm focal spot. In addition, high-quality 3D imaging of lithium-ion batteries (LIBs) is demonstrated with a scan time as low as 2 s and a contrast-to-noise ratio exceeding 3. By overcoming the trade-off between the spatial resolution and the scan time in X-ray imaging, the proposed system enables high-throughput in-line inspection of mass-produced LIBs.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-11-21
DOI
https://doi.org/10.1002/advs.202517158
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optically‐Coupled X‐Ray Computed Laminography System for High‐Speed Inspection of Lithium‐Ion Batteries

Jaeyoung Im, Seunguk Cheon, Jun Kim, J.N. Heo et al.
Advanced Science
Advanced X-ray and CT Imaging
article

Optically‐Coupled X‐Ray Computed Laminography System for High‐Speed Inspection of Lithium‐Ion Batteries

Jaeyoung Im, Seunguk Cheon, Jun Kim, J.N. Heo, Sung Oh Cho
article en

Abstract

Conventional X-ray computed tomography systems for microstructure inspection typically employ a geometrically magnified imaging setup, requiring a micro-focus X-ray source to mitigate image blurring caused by a finite focal spot size. However, due to its low output power, the micro-focus X-ray source results in prolonged image acquisition times. This study presents a novel optically-coupled X-ray computed laminography system for high-speed inspection. In the proposed system, a scintillator is placed in contact with an object, effectively minimizing image blurring despite the use of an X-ray source with a large focal spot. Consequently, a high-power X-ray tube can be employed without compromising spatial resolution, leading to a significant reduction in scan time. Modulation transfer function analysis confirms that a spatial resolution of 38 µm is achieved using a high-power (400 W) X-ray tube with a 400 µm focal spot. In addition, high-quality 3D imaging of lithium-ion batteries (LIBs) is demonstrated with a scan time as low as 2 s and a contrast-to-noise ratio exceeding 3. By overcoming the trade-off between the spatial resolution and the scan time in X-ray imaging, the proposed system enables high-throughput in-line inspection of mass-produced LIBs.

Advanced ScienceVol. 13(7)
Korea Advanced Institute of Science and Technology (KR)
Ministry of Science and ICT, South Korea
Openalex Percentile: Top 65%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.