Mechanochemical Optimization of Composite–Substrate Interfaces for Durable Repair Adhesion to Metal and Zirconia: An In Vitro Study

Background/Objectives: Achieving durable intraoral repairs of fractured metal and zirconia restorations requires optimal adhesion. This in vitro study evaluated the effects of mechanical surface treatments and commercial repair systems on the shear bond strength (SBS) of composite resin to nickel–chromium (Ni-Cr) alloy and zirconia, including the influence of thermocycling aging. Methods: In this study, 144 Ni-Cr and zirconia discs (12 × 12 × 2 mm) were randomly assigned to three surface treatments: untreated control, airborne particle abrasion (50 µm Al2O3), and medium grit diamond bur grinding. Each group was further subdivided to assess two intraoral repair kits (GC Corp (Tokyo, Japan). and Bisco Inc. (Schaumburg, IL, USA)). Composite resin cylinders were bonded following the manufacturer’s instructions. Half of the specimens (n = 12/subgroup) underwent 5000 thermocycles (5–55 °C). Micro-shear bond strength testing was performed, and failure modes were analyzed. Data were analyzed using three-way ANOVA and post hoc tests (p < 0.05). Results: Air abrasion significantly increased SBS compared to control and bur grinding for metal (p < 0.001). For zirconia, both air abrasion and bur grinding yielded similarly improved SBS over the control (p < 0.001). The GC repair kit demonstrated significantly superior bond stability after thermocycling across both substrates. Aging significantly reduced SBS in all groups (p < 0.001), with the most substantial reductions observed in untreated controls and groups repaired with the Bisco system. Conclusions: Airborne particle abrasion combined with a HEMA-free, 10-MDP-containing universal adhesive achieved the strongest and most durable resin bonds to both metal and zirconia, supporting its clinical use for the intraoral repair of ceramic and metal restorations.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2025-11-21
DOI
https://doi.org/10.3390/prosthesis7060151
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanochemical Optimization of Composite–Substrate Interfaces for Durable Repair Adhesion to Metal and Zirconia: An In Vitro Study

B. Sharif, Hawzhen Masoud Mohammed Saeed
Prosthesis
Dental materials and restorations
article

Mechanochemical Optimization of Composite–Substrate Interfaces for Durable Repair Adhesion to Metal and Zirconia: An In Vitro Study

B. Sharif, Hawzhen Masoud Mohammed Saeed
article en

Abstract

Background/Objectives: Achieving durable intraoral repairs of fractured metal and zirconia restorations requires optimal adhesion. This in vitro study evaluated the effects of mechanical surface treatments and commercial repair systems on the shear bond strength (SBS) of composite resin to nickel–chromium (Ni-Cr) alloy and zirconia, including the influence of thermocycling aging. Methods: In this study, 144 Ni-Cr and zirconia discs (12 × 12 × 2 mm) were randomly assigned to three surface treatments: untreated control, airborne particle abrasion (50 µm Al2O3), and medium grit diamond bur grinding. Each group was further subdivided to assess two intraoral repair kits (GC Corp (Tokyo, Japan). and Bisco Inc. (Schaumburg, IL, USA)). Composite resin cylinders were bonded following the manufacturer’s instructions. Half of the specimens (n = 12/subgroup) underwent 5000 thermocycles (5–55 °C). Micro-shear bond strength testing was performed, and failure modes were analyzed. Data were analyzed using three-way ANOVA and post hoc tests (p < 0.05). Results: Air abrasion significantly increased SBS compared to control and bur grinding for metal (p < 0.001). For zirconia, both air abrasion and bur grinding yielded similarly improved SBS over the control (p < 0.001). The GC repair kit demonstrated significantly superior bond stability after thermocycling across both substrates. Aging significantly reduced SBS in all groups (p < 0.001), with the most substantial reductions observed in untreated controls and groups repaired with the Bisco system. Conclusions: Airborne particle abrasion combined with a HEMA-free, 10-MDP-containing universal adhesive achieved the strongest and most durable resin bonds to both metal and zirconia, supporting its clinical use for the intraoral repair of ceramic and metal restorations.

ProsthesisVol. 7(6)
University of Sulaimani (IQ)
Openalex Percentile: Top 59%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanochemical Optimization of Composite–Substrate Interfaces for Durable Repair Adhesion to Metal and Zirconia: An In Vitro Study — B. Sharif, Hawzhen Masoud Mohammed Saeed · Prosthesis (2025) | TGRS Research Map | TGRS