Precision and trueness of a method for determing antimony content in groundwater using hydride generation-atomic fluorescence spectrometry

At present, there is currently a lack of unified standard methods for the determination of antimony content in groundwater in China. The precision and trueness of related detection technologies have not yet been systematically and quantitatively evaluated, which limits the effective implementation of environmental monitoring. In response to this key technical gap, this study aimed to establish a standardized method for determining antimony in groundwater using hydride generation–atomic fluorescence spectrometry (HG-AFS). Ten laboratories participated in inter-laboratory collaborative tests, and the statistical analysis of the test data was carried out in strict accordance with the technical specifications of GB/T 6379.2—2004 and GB/T 6379.4—2006. The consistency and outliers of the data were tested by Mandel's <i>h</i> and <i>k</i> statistics, the Grubbs test and the Cochran test, and the outliers were removed to optimize the data, thereby significantly improving the reliability and accuracy. Based on the optimized data, parameters such as the repeatability limit (<i>r</i>), reproducibility limit (<i>R</i>), and method bias value (<i>δ</i>) were determined, and the trueness of the method was statistically evaluated. At the same time, precision-function relationships were established, and all results met the requirements. The results show that the lower the antimony content, the lower the repeatability limit (<i>r</i>) and reproducibility limit (<i>R</i>), indicating that the measurement error mainly originates from the detection limit of the method and instrument sensitivity. Therefore, improving the instrument sensitivity and reducing the detection limit are the keys to controlling the analytical error and improving precision. This study provides reliable data support and a solid technical foundation for the establishment and evaluation of standardized methods for the determination of antimony content in groundwater.

Authors

Institutions

Publication Details

Journal
Journal of Groundwater Science and Engineering
Published
2025-11-21
DOI
https://doi.org/10.26599/jgse.2026.9280071
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision and trueness of a method for determing antimony content in groundwater using hydride generation-atomic fluorescence spectrometry

Ke Li, Lin Zhang, Bingbing Liu
Journal of Groundwater Science and Engineering
Analytical chemistry methods development
article

Precision and trueness of a method for determing antimony content in groundwater using hydride generation-atomic fluorescence spectrometry

Ke Li, Lin Zhang, Bingbing Liu
article en

Abstract

At present, there is currently a lack of unified standard methods for the determination of antimony content in groundwater in China. The precision and trueness of related detection technologies have not yet been systematically and quantitatively evaluated, which limits the effective implementation of environmental monitoring. In response to this key technical gap, this study aimed to establish a standardized method for determining antimony in groundwater using hydride generation–atomic fluorescence spectrometry (HG-AFS). Ten laboratories participated in inter-laboratory collaborative tests, and the statistical analysis of the test data was carried out in strict accordance with the technical specifications of GB/T 6379.2—2004 and GB/T 6379.4—2006. The consistency and outliers of the data were tested by Mandel's <i>h</i> and <i>k</i> statistics, the Grubbs test and the Cochran test, and the outliers were removed to optimize the data, thereby significantly improving the reliability and accuracy. Based on the optimized data, parameters such as the repeatability limit (<i>r</i>), reproducibility limit (<i>R</i>), and method bias value (<i>δ</i>) were determined, and the trueness of the method was statistically evaluated. At the same time, precision-function relationships were established, and all results met the requirements. The results show that the lower the antimony content, the lower the repeatability limit (<i>r</i>) and reproducibility limit (<i>R</i>), indicating that the measurement error mainly originates from the detection limit of the method and instrument sensitivity. Therefore, improving the instrument sensitivity and reducing the detection limit are the keys to controlling the analytical error and improving precision. This study provides reliable data support and a solid technical foundation for the establishment and evaluation of standardized methods for the determination of antimony content in groundwater.

Journal of Groundwater Science and EngineeringVol. 14(1)
China Geological Survey (CN), Chinese Academy of Geological Sciences (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 61%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.