Multi-sensor passive manikin — verification and potential applications for improving human safety, health, comfort and energy efficiency

• A new method using a multi-sensor passive manikin to monitor human thermal exposure • Novel on-site calibration methods improve sensor accuracy for all thermal parameters • Mapping HVAC manikin to multiple thermoregulation models enables physiological prediction • Sensitivity analysis reveals air speed errors as key model output influencers • HVAC manikin application supports safer, energy-efficient designs in diverse environments The physical environment surrounding the human body, including the air temperature, air speed, relative humidity, and radiant heat flux, has a strong impact on human well-being. However, studies involving high-resolution, multi-dimensional, and quantitative characterisation of human exposure to different scenarios, especially in highly heterogeneous or potentially unsafe conditions, remain lacking. Conventional stand-alone environmental sensors often fail to capture the spatial variability and combined loads actually experienced at the body surface. This study aims to develop a new method, based on a multi-sensor passive manikin, of monitoring human exposure in unprecedented detail. Since this manikin was used for the first time in scientific research, it underwent scrutiny evaluation and corrective measures for undesired effects of electronic heating during long-term operation were proposed. Even though each sensor had been factory-calibrated, we established and tested systematic on-site calibration procedures for each sensor type directly on the manikin surface for ease of use in lab and field conditions. We then developed strategies for mapping the different thermo-physiological model segmentations and the manikin zones. The results show clear differences before and after calibration across various environmental conditions. A sensitivity analysis in combination with the thermo-physiological model revealed that measurement inaccuracies from air speed sensors are the primary source of error affecting the predicted human thermal responses. In general, the calibrated HVAC manikin outperforms a sparse set of conventional sensors by providing anatomically distributed, multi-parameter, and high-resolution measurements, providing a reliable tool without ethical constraints for improving human health and safety, thermal comfort, and energy efficiency.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-11-16
DOI
https://doi.org/10.1016/j.rineng.2025.108205
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-sensor passive manikin — verification and potential applications for improving human safety, health, comfort and energy efficiency

René M. Rossi, Agnes Psikuta, Zhuqiang Hu
1 citations
Results in Engineering
Building Energy and Comfort Optimization
1.01
article

Multi-sensor passive manikin — verification and potential applications for improving human safety, health, comfort and energy efficiency

René M. Rossi, Agnes Psikuta, Zhuqiang Hu
article en
1 citations

Abstract

• A new method using a multi-sensor passive manikin to monitor human thermal exposure • Novel on-site calibration methods improve sensor accuracy for all thermal parameters • Mapping HVAC manikin to multiple thermoregulation models enables physiological prediction • Sensitivity analysis reveals air speed errors as key model output influencers • HVAC manikin application supports safer, energy-efficient designs in diverse environments The physical environment surrounding the human body, including the air temperature, air speed, relative humidity, and radiant heat flux, has a strong impact on human well-being. However, studies involving high-resolution, multi-dimensional, and quantitative characterisation of human exposure to different scenarios, especially in highly heterogeneous or potentially unsafe conditions, remain lacking. Conventional stand-alone environmental sensors often fail to capture the spatial variability and combined loads actually experienced at the body surface. This study aims to develop a new method, based on a multi-sensor passive manikin, of monitoring human exposure in unprecedented detail. Since this manikin was used for the first time in scientific research, it underwent scrutiny evaluation and corrective measures for undesired effects of electronic heating during long-term operation were proposed. Even though each sensor had been factory-calibrated, we established and tested systematic on-site calibration procedures for each sensor type directly on the manikin surface for ease of use in lab and field conditions. We then developed strategies for mapping the different thermo-physiological model segmentations and the manikin zones. The results show clear differences before and after calibration across various environmental conditions. A sensitivity analysis in combination with the thermo-physiological model revealed that measurement inaccuracies from air speed sensors are the primary source of error affecting the predicted human thermal responses. In general, the calibrated HVAC manikin outperforms a sparse set of conventional sensors by providing anatomically distributed, multi-parameter, and high-resolution measurements, providing a reliable tool without ethical constraints for improving human health and safety, thermal comfort, and energy efficiency.

Results in EngineeringVol. 28
ETH Zurich (CH), Swiss Federal Laboratories for Materials Science and Technology (CH)
Openalex Percentile: Top 18%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.