A novel technique for labeling of primary antibodies with fluorophores for increased brightness: FlexAble 20 9290

Abstract Description FlexAble is an innovative antibody labeling approach that simplifies rapid conjugation of primary antibodies to fluorophores, enabling efficient same-species multiplex immunofluorescence. This labeling solution allows researchers to functionalize primary IgGs with desired fluorophores via a simple mixing and incubation process, requiring only 10 minutes, with no specialized equipment or chemical expertise needed. FlexAble labeling is compatible with primary antibody buffers from any supplier, as glycerol and other additives do not interfere with the reaction. With FlexAble 2.0, we achieve up to a 300% increase in signal intensity compared to FlexAble 1.0, delivering enhanced brightness and versatility for complex multiplex assays. We are further expanding this method to label primary antibodies with reporter proteins (e.g., HRP, PE, APC), biotin, DNA oligonucleotides, rare-earth metals, and more. These developments support applications in multiplex flow cytometry, nucleotide barcoding (e.g., 10x Genomics), and IMC (e.g., CyTOF). Topic Categories Technological Innovations in Immunology (TECH)

Authors

Publication Details

Journal
The Journal of Immunology
Published
2025-11-01
DOI
https://doi.org/10.1093/jimmun/vkaf283.2713
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel technique for labeling of primary antibodies with fluorophores for increased brightness: FlexAble 20 9290

Danielle Callahan
The Journal of Immunology
Advanced Biosensing Techniques and Applications
article

A novel technique for labeling of primary antibodies with fluorophores for increased brightness: FlexAble 20 9290

Danielle Callahan
article en

Abstract

Abstract Description FlexAble is an innovative antibody labeling approach that simplifies rapid conjugation of primary antibodies to fluorophores, enabling efficient same-species multiplex immunofluorescence. This labeling solution allows researchers to functionalize primary IgGs with desired fluorophores via a simple mixing and incubation process, requiring only 10 minutes, with no specialized equipment or chemical expertise needed. FlexAble labeling is compatible with primary antibody buffers from any supplier, as glycerol and other additives do not interfere with the reaction. With FlexAble 2.0, we achieve up to a 300% increase in signal intensity compared to FlexAble 1.0, delivering enhanced brightness and versatility for complex multiplex assays. We are further expanding this method to label primary antibodies with reporter proteins (e.g., HRP, PE, APC), biotin, DNA oligonucleotides, rare-earth metals, and more. These developments support applications in multiplex flow cytometry, nucleotide barcoding (e.g., 10x Genomics), and IMC (e.g., CyTOF). Topic Categories Technological Innovations in Immunology (TECH)

The Journal of ImmunologyVol. 214(Supplement_1)
Openalex Percentile: Top 68%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.