Endovascular aortic repair with iliac branch endoprosthesis for short common iliac aneurysm

Iliac branch endoprosthesis is an effective method for preserving the internal iliac artery blood flow during endovascular aortic repair. We describe the case of a right common iliac artery aneurysm complicated by a left internal iliac artery occlusion in a 74-year-old man. To preserve perfusion of the right internal iliac artery in a patient with a short common iliac artery, an iliac branch endoprosthesis device was connected to the AFX and deployed 15 mm above the aortic bifurcation. The absence of an endoleak on postoperative computed tomography indicated technical success and potential effectiveness of the procedure.

Authors

Institutions

Publication Details

Journal
Journal of Vascular Surgery Cases and Innovative Techniques
Published
2025-11-21
DOI
https://doi.org/10.1016/j.jvscit.2025.102066
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endovascular aortic repair with iliac branch endoprosthesis for short common iliac aneurysm

Kazuo Shimamura, Takashi Shirakawa, Fumio Yamana, Yoshiki Watanabe et al.
Journal of Vascular Surgery Cases and Innovative Techniques
Aortic aneurysm repair treatments
article

Endovascular aortic repair with iliac branch endoprosthesis for short common iliac aneurysm

Kazuo Shimamura, Takashi Shirakawa, Fumio Yamana, Yoshiki Watanabe, Satoshi Sakakibara, Shigeru Miyagawa
article en

Abstract

Iliac branch endoprosthesis is an effective method for preserving the internal iliac artery blood flow during endovascular aortic repair. We describe the case of a right common iliac artery aneurysm complicated by a left internal iliac artery occlusion in a 74-year-old man. To preserve perfusion of the right internal iliac artery in a patient with a short common iliac artery, an iliac branch endoprosthesis device was connected to the AFX and deployed 15 mm above the aortic bifurcation. The absence of an endoleak on postoperative computed tomography indicated technical success and potential effectiveness of the procedure.

Journal of Vascular Surgery Cases and Innovative TechniquesVol. 12(1)
The University of Osaka (JP)
Openalex Percentile: Top 49%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.