FBFormer: interventional ultra-sparse CT reconstruction with image prior using feature back-projection and transformer

<i>Objective</i>. CT-guided interventional procedures hold a significant position in clinical practice. However, due to the high number of scans and prolonged procedure times, patients are exposed to considerable radiation doses. This study aims to utilize intraoperative x-ray imaging as an alternative to intraoperative CT guidance, integrating preoperative prior scan images to reconstruct interventional CT.<i>Approach</i>. We present Feature back-projection Transformer (FBFormer), a reconstruction framework using Transformer and a novel feature back-projection module to reconstruct tomographic data from ultra-sparse(less than 10 views) intraoperative x-ray images. A mixed UNet and PVT encoder is employed to extract the local and global feature of the x-ray images and preoperative image prior, supporting more various input, while a feature back-projection module is utilized to achieve 2D-3D conversion in a more natural and geometrically consistent manner.<i>Main Results</i>. Extensive experiments on our simulated 4DCT and clinical validation datasets demonstrate the effectiveness of the proposed method and our method achieves superior results in reconstruction performance metrics and outperforms other compelling methods.<i>Significance</i>. The proposed method has the potential to significantly reduce radiation exposure during interventional procedures while maintaining high-quality reconstruction. The proposed FBFormer framework demonstrates the potential to enhance the clinical reliability of interventional CT reconstruction from ultra-sparse x-ray projections by the integration of image priors and the geometric preserving feature back-projection module.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-20
DOI
https://doi.org/10.1088/1361-6560/ae222b
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FBFormer: interventional ultra-sparse CT reconstruction with image prior using feature back-projection and transformer

Siyou Li, Wangyuan Zhao, Zefan Lin, Guotao Quan et al.
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

FBFormer: interventional ultra-sparse CT reconstruction with image prior using feature back-projection and transformer

Siyou Li, Wangyuan Zhao, Zefan Lin, Guotao Quan, Jun Zhao, Yuan Liu, Ziheng Deng, Y. P. Pei
article en

Abstract

<i>Objective</i>. CT-guided interventional procedures hold a significant position in clinical practice. However, due to the high number of scans and prolonged procedure times, patients are exposed to considerable radiation doses. This study aims to utilize intraoperative x-ray imaging as an alternative to intraoperative CT guidance, integrating preoperative prior scan images to reconstruct interventional CT.<i>Approach</i>. We present Feature back-projection Transformer (FBFormer), a reconstruction framework using Transformer and a novel feature back-projection module to reconstruct tomographic data from ultra-sparse(less than 10 views) intraoperative x-ray images. A mixed UNet and PVT encoder is employed to extract the local and global feature of the x-ray images and preoperative image prior, supporting more various input, while a feature back-projection module is utilized to achieve 2D-3D conversion in a more natural and geometrically consistent manner.<i>Main Results</i>. Extensive experiments on our simulated 4DCT and clinical validation datasets demonstrate the effectiveness of the proposed method and our method achieves superior results in reconstruction performance metrics and outperforms other compelling methods.<i>Significance</i>. The proposed method has the potential to significantly reduce radiation exposure during interventional procedures while maintaining high-quality reconstruction. The proposed FBFormer framework demonstrates the potential to enhance the clinical reliability of interventional CT reconstruction from ultra-sparse x-ray projections by the integration of image priors and the geometric preserving feature back-projection module.

Physics in Medicine and BiologyVol. 70(23)
Shanghai Jiao Tong University (CN), United Imaging Healthcare (China) (CN)
Openalex Percentile: Top 50%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.