Evaluation of smartphone swabs as a toxicological analysis matrix: A controlled study in hospitalized patients

Invasive sampling limits the scope of psychoactive drug and toxic substance detection. Latent papillary trace (LPT) analysis offers a non-invasive alternative matrix, but controlled data are lacking. This study aimed to assess the performance of smartphone swab (SS) analysis as a toxicological screening tool in hospitalized patients with known medication regimens. A prospective study was conducted on adult patients from the forensic medicine and psychiatry departments of Grenoble Alpes University Hospital. SS and routine blood samples were collected and analyzed for the screening of 349 drugs using UPLC-MS/MS. Hospital records provided prescribed medications. A contamination on laboratory volunteers' smartphones tested the persistence of 11 drugs after handling. Twenty-one patients (aged 18-76, 67 % female) were included. A perfect match between detected molecules was observed between SS and blood in 24 % of cases, and between SS and recorded treatments in 14 % of cases. Of the drugs identified, 54 % were present both on the SS and in the blood, mainly benzodiazepines, opioid analgesics and selective serotonin reuptake inhibitors antidepressants. Some drugs were exclusively detected in blood (e.g., antihypertensives), while others appeared on SS but not in blood or treatment records. The contamination study showed persistence of 10/11 drugs on smartphones for up to three weeks. SS represents an innovative approach for screening specific drug classes but faces limitations due to environmental contamination, prior exposure, and the non-detection of certain substances present in blood. Cautious interpretation and further research are crucial to establish SS as a reliable toxicological tool.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical and Biomedical Analysis
Published
2025-11-13
DOI
https://doi.org/10.1016/j.jpba.2025.117241
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of smartphone swabs as a toxicological analysis matrix: A controlled study in hospitalized patients

Théo Willeman, Françoise Stanke‐Labesque, A. Fort, Anne-Sophie Nguon et al.
Journal of Pharmaceutical and Biomedical Analysis
Forensic Toxicology and Drug Analysis
article

Evaluation of smartphone swabs as a toxicological analysis matrix: A controlled study in hospitalized patients

Théo Willeman, Françoise Stanke‐Labesque, A. Fort, Anne-Sophie Nguon, Coralie Boudin, Hélène Eysseric‐Guerin, V. Scolan
article en

Abstract

Invasive sampling limits the scope of psychoactive drug and toxic substance detection. Latent papillary trace (LPT) analysis offers a non-invasive alternative matrix, but controlled data are lacking. This study aimed to assess the performance of smartphone swab (SS) analysis as a toxicological screening tool in hospitalized patients with known medication regimens. A prospective study was conducted on adult patients from the forensic medicine and psychiatry departments of Grenoble Alpes University Hospital. SS and routine blood samples were collected and analyzed for the screening of 349 drugs using UPLC-MS/MS. Hospital records provided prescribed medications. A contamination on laboratory volunteers' smartphones tested the persistence of 11 drugs after handling. Twenty-one patients (aged 18-76, 67 % female) were included. A perfect match between detected molecules was observed between SS and blood in 24 % of cases, and between SS and recorded treatments in 14 % of cases. Of the drugs identified, 54 % were present both on the SS and in the blood, mainly benzodiazepines, opioid analgesics and selective serotonin reuptake inhibitors antidepressants. Some drugs were exclusively detected in blood (e.g., antihypertensives), while others appeared on SS but not in blood or treatment records. The contamination study showed persistence of 10/11 drugs on smartphones for up to three weeks. SS represents an innovative approach for screening specific drug classes but faces limitations due to environmental contamination, prior exposure, and the non-detection of certain substances present in blood. Cautious interpretation and further research are crucial to establish SS as a reliable toxicological tool.

Journal of Pharmaceutical and Biomedical AnalysisVol. 269
Inserm (FR), Centre Hospitalier Universitaire de Grenoble (FR), Laboratoire Rhéologie et Procédés (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 65%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.