When to trust the answer: question-aligned semantic nearest neighbor entropy for safer surgical VQA

PURPOSE: Future human-in-the-loop surgical visual question answering (VQA) requires detecting unreliable answers before use. In this preclinical methodological study, we distinguish answer consistency from question validity: A model may generate mutually consistent answers that still fail to address the clinical question. METHODS: We propose question-aligned semantic nearest neighbor entropy (QA-SNNE), a black-box failure-detection score that adds question-answer alignment to semantic entropy through bilateral gating. QA-SNNE modulates pairwise similarities among sampled answers by their question relevance, using embedding, entailment, or cross-encoder alignment. To assess robustness under language variation, we construct an out-of-template rephrased version of a benchmark surgical VQA dataset, in which only the question wording is modified while images and ground-truth answers remain unchanged. RESULTS: We evaluate QA-SNNE on five VQA models across two benchmark surgical VQA datasets, considering both zero-shot and parameter-efficient fine-tuned settings, including out-of-template questions. QA-SNNE improves AUROC on EndoVis18-VQA for two of three zero-shot models in-template (e.g., +15% for Llama3.2 and +21% for Qwen2.5) and achieves up to +8% AUROC relative improvement among zero-shot models under out-of-template rephrasing, with mixed results on external validation. CONCLUSION: By making uncertainty estimation explicitly question-aware, QA-SNNE provides a practical and model-agnostic safeguard for preclinical surgical VQA evaluation. Linking semantic uncertainty to question relevance enables more reliable failure detection under variation in question phrasing.

Authors

Institutions

Publication Details

Journal
International Journal of Computer Assisted Radiology and Surgery
Published
2026-07-17
DOI
https://doi.org/10.1007/s11548-026-03750-9
Primary Topic
Multimodal Machine Learning Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

When to trust the answer: question-aligned semantic nearest neighbor entropy for safer surgical VQA

Cesare Hassan, Chiara Lena, Sophia Bano, Danail Stoyanov et al.
International Journal of Computer Assisted Radiology and Surgery
Multimodal Machine Learning Applications
article

When to trust the answer: question-aligned semantic nearest neighbor entropy for safer surgical VQA

Cesare Hassan, Chiara Lena, Sophia Bano, Danail Stoyanov, Luca Carlini, Mauro Orazio Drago, Dennis Pierantozzi
article en

Abstract

PURPOSE: Future human-in-the-loop surgical visual question answering (VQA) requires detecting unreliable answers before use. In this preclinical methodological study, we distinguish answer consistency from question validity: A model may generate mutually consistent answers that still fail to address the clinical question. METHODS: We propose question-aligned semantic nearest neighbor entropy (QA-SNNE), a black-box failure-detection score that adds question-answer alignment to semantic entropy through bilateral gating. QA-SNNE modulates pairwise similarities among sampled answers by their question relevance, using embedding, entailment, or cross-encoder alignment. To assess robustness under language variation, we construct an out-of-template rephrased version of a benchmark surgical VQA dataset, in which only the question wording is modified while images and ground-truth answers remain unchanged. RESULTS: We evaluate QA-SNNE on five VQA models across two benchmark surgical VQA datasets, considering both zero-shot and parameter-efficient fine-tuned settings, including out-of-template questions. QA-SNNE improves AUROC on EndoVis18-VQA for two of three zero-shot models in-template (e.g., +15% for Llama3.2 and +21% for Qwen2.5) and achieves up to +8% AUROC relative improvement among zero-shot models under out-of-template rephrasing, with mixed results on external validation. CONCLUSION: By making uncertainty estimation explicitly question-aware, QA-SNNE provides a practical and model-agnostic safeguard for preclinical surgical VQA evaluation. Linking semantic uncertainty to question relevance enables more reliable failure detection under variation in question phrasing.

International Journal of Computer Assisted Radiology and Surgery
University of Manchester (GB), The London College (GB), IRCCS Humanitas Research Hospital (IT), University College London (GB), Politecnico di Milano (IT)
UK Research and Innovation, Royal Academy of Engineering, European Commission, Politecnico di Milano, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 98%
Multimodal Machine Learning Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.