An In-Depth Study on Device Variability in 22 nm FD-SOI NMOSFETs Under X-Ray Exposure

The effect of total-ionizing-dose (TID) on device-to-device variability in 22 nm FD-SOI NMOS transistors was experimentally quantified. Across ten <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W/L</i> geometries, two device types (RVT, LVT), and three irradiation-bias conditions (Off-Stress, Work-Mode, Power-Off), ensembles of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</i> = 80 devices per geometry, 4800 transistors in total were irradiated to 300 krad(SiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) and subsequently characterized. Pelgrom plots of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V<sub>th</sub></i> and the current-factor β were analyzed. TID consistently shifted <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><sub>th</sub></sub> negative and broadened its distribution while preserving the 1/ √ <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">WL</i> law; the extracted <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">A<sub>V</sub><sub>th</sub></i> increased by about 9–47% depending on bias/type, with a robust ordering <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Off-Stress</i> > <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Work-Mode</i> > <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Power-Off</i>. In contrast, β exhibited near-zero mean drift and only modest variance growth (typically ≤20%), indicating a much weaker mobility-driven response. Size-segregated fits confirmed an <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">area-dominated</i> mechanism: small-area devices exhibited the largest variance increase, whereas large-area devices approached the measurement floor. A compact dose-aware Pelgrom model was established, adding a TID-dependent term to <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">A<sub>V</sub><sub>th</sub></i> that links the Poisson-distributed BOX trapped charge and the bias-dependent electrostatic coupling, and captures the observed bias ordering and size scaling.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2025-11-20
DOI
https://doi.org/10.1109/tns.2025.3635536
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An In-Depth Study on Device Variability in 22 nm FD-SOI NMOSFETs Under X-Ray Exposure

Yihong Qing, Zheyi Li, Luc de Hoÿm de Marien, Paul Leroux et al.
IEEE Transactions on Nuclear Science
Radiation Effects in Electronics
article

An In-Depth Study on Device Variability in 22 nm FD-SOI NMOSFETs Under X-Ray Exposure

Yihong Qing, Zheyi Li, Luc de Hoÿm de Marien, Paul Leroux, Tadec Maraine, Jinghao Zhao, Maxim S. Gorbunov, Pengfei Xu, Xue Fan, Jeffrey Prinzie, Qichao Ma, Frédéric Saigné
article en

Abstract

The effect of total-ionizing-dose (TID) on device-to-device variability in 22 nm FD-SOI NMOS transistors was experimentally quantified. Across ten <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W/L</i> geometries, two device types (RVT, LVT), and three irradiation-bias conditions (Off-Stress, Work-Mode, Power-Off), ensembles of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</i> = 80 devices per geometry, 4800 transistors in total were irradiated to 300 krad(SiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) and subsequently characterized. Pelgrom plots of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V<sub>th</sub></i> and the current-factor β were analyzed. TID consistently shifted <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><sub>th</sub></sub> negative and broadened its distribution while preserving the 1/ √ <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">WL</i> law; the extracted <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">A<sub>V</sub><sub>th</sub></i> increased by about 9–47% depending on bias/type, with a robust ordering <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Off-Stress</i> > <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Work-Mode</i> > <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Power-Off</i>. In contrast, β exhibited near-zero mean drift and only modest variance growth (typically ≤20%), indicating a much weaker mobility-driven response. Size-segregated fits confirmed an <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">area-dominated</i> mechanism: small-area devices exhibited the largest variance increase, whereas large-area devices approached the measurement floor. A compact dose-aware Pelgrom model was established, adding a TID-dependent term to <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">A<sub>V</sub><sub>th</sub></i> that links the Poisson-distributed BOX trapped charge and the bias-dependent electrostatic coupling, and captures the observed bias ordering and size scaling.

IEEE Transactions on Nuclear ScienceVol. 73(2)
Centre National de la Recherche Scientifique (FR), Université de Montpellier (FR), iMinds (BE), IMEC (BE), KU Leuven (BE)
Openalex Percentile: Top 65%
Radiation Effects in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.