BabyMOSS stitched sensors: results of characterisation tests for ALICE ITS3 upgrade

Abstract During the Long Shutdown 3 (LS3, scheduled 2026–2030), the innermost 3 layers (Inner Barrel, or IB) of the present ALICE ITS2 will be replaced with large-area, flexible, stitched CMOS 65 nm sensors, arranged in 2 half-barrels of 3 half-layers each, in the framework of the ITS3 upgrade project. For the first time in a High Energy Physics experiment, such large-scale sensors will be bent into truly half-cylindrical shaped half-layers, requiring little mechanical support. This will also help lower the material budget: a reduction down to an average of 0.09% X 0 per layer is expected, benefitting ITS tracking and vertexing capabilities especially at low momenta. In the wafer yield and stitching assessment stage for ITS3 R&D, test devices from the Engineering Run 1 (ER1) submission were developed, including the MOnolithic Stiched Sensors (MOSS) and smaller variants of them (babyMOSS). In particular, babyMOSS is a single Repeated Sensor Unit (RSU) of a MOSS device: the chip is ∼14×30 mm 2 in size, and consists of 8 digitally read out pixel matrices (regions) arranged in 2 rows, i.e. half-units (HUs). BabyMOSS chip characterisation tests have been performed in laboratory and test beam environments. Laboratory tests include systematic functional scans to study the behaviour of front-end electronics over a range of different settings, whereas test beam measurements, under high-energy charged particle beams, were used to investigate the detection efficiency and spatial resolution. In this contribution, we will present the babyMOSS chip characterisation campaign, with a focus on recent test beam results. So far, babyMOSS test beam results have been consistent with full MOSS, and confirmed that babyMOSS devices meet the ITS3 requirements: a detection efficiency > 99%, fake hit rate < 10 -6 hits per pixel and event, and a spatial resolution < 6 μm.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-11-01
DOI
https://doi.org/10.1088/1748-0221/20/11/c11007
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BabyMOSS stitched sensors: results of characterisation tests for ALICE ITS3 upgrade

A. Sturniolo
Journal of Instrumentation
Particle Detector Development and Performance
article

BabyMOSS stitched sensors: results of characterisation tests for ALICE ITS3 upgrade

A. Sturniolo
article en

Abstract

Abstract During the Long Shutdown 3 (LS3, scheduled 2026–2030), the innermost 3 layers (Inner Barrel, or IB) of the present ALICE ITS2 will be replaced with large-area, flexible, stitched CMOS 65 nm sensors, arranged in 2 half-barrels of 3 half-layers each, in the framework of the ITS3 upgrade project. For the first time in a High Energy Physics experiment, such large-scale sensors will be bent into truly half-cylindrical shaped half-layers, requiring little mechanical support. This will also help lower the material budget: a reduction down to an average of 0.09% X 0 per layer is expected, benefitting ITS tracking and vertexing capabilities especially at low momenta. In the wafer yield and stitching assessment stage for ITS3 R&D, test devices from the Engineering Run 1 (ER1) submission were developed, including the MOnolithic Stiched Sensors (MOSS) and smaller variants of them (babyMOSS). In particular, babyMOSS is a single Repeated Sensor Unit (RSU) of a MOSS device: the chip is ∼14×30 mm 2 in size, and consists of 8 digitally read out pixel matrices (regions) arranged in 2 rows, i.e. half-units (HUs). BabyMOSS chip characterisation tests have been performed in laboratory and test beam environments. Laboratory tests include systematic functional scans to study the behaviour of front-end electronics over a range of different settings, whereas test beam measurements, under high-energy charged particle beams, were used to investigate the detection efficiency and spatial resolution. In this contribution, we will present the babyMOSS chip characterisation campaign, with a focus on recent test beam results. So far, babyMOSS test beam results have been consistent with full MOSS, and confirmed that babyMOSS devices meet the ITS3 requirements: a detection efficiency > 99%, fake hit rate < 10 -6 hits per pixel and event, and a spatial resolution < 6 μm.

Journal of InstrumentationVol. 20(11)
University of Messina (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Catania (IT)
Openalex Percentile: Top 84%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

BabyMOSS stitched sensors: results of characterisation tests for ALICE ITS3 upgrade — A. Sturniolo · Journal of Instrumentation (2025) | TGRS Research Map | TGRS