Pediatric CNS relapse of neuroblastoma treated with upright proton craniospinal irradiation

Craniospinal irradiation (CSI) is a technically demanding treatment in pediatric oncology, especially for young children, who often require daily anesthesia. Although proton therapy offers dosimetric advantages over photons by eliminating exit dose and reducing exposure to healthy tissues, its global availability is limited due to the cost and complexity of gantry-based systems. Recently, gantry-less proton therapy with upright positioning has recently emerged as a compact, cost-efficient alternative, integrating robotic positioning and vertical CT-based image guidance. This study reports the first pediatric case of upright proton CSI delivered under intravenous monitored anesthesia care (MAC) using such a system. A four-year-old male patient with relapsed neuroblastoma in the central nervous system received CSI at a dose of 18.0 Gy(RBE) in 12 fractions, along with a simultaneous integrated boost (SIB) of 21.6 Gy(RBE) to the resection cavity. This was followed by a sequential boost to the resection cavity in five fractions, for a total dose of 30.6 Gy(RBE). The treatment was performed in the seated position with customized immobilization, upright volumetric CT verification, and reproducible daily setup. MAC achieved without intubation, allowing continuous airway access. The patient completed the treatment regimen without interruption, did not experience any grade 2 or higher acute toxicities, and demonstrated adequate tolerance of daily anesthesia. This case demonstrates the clinical feasibility of upright proton CSI under MAC and provides proof of concept for the broader adoption of gantry-less proton therapy in complicated cases.

Authors

Institutions

Publication Details

Journal
Clinical and Translational Radiation Oncology
Published
2025-11-20
DOI
https://doi.org/10.1016/j.ctro.2025.101080
Primary Topic
Neuroblastoma Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pediatric CNS relapse of neuroblastoma treated with upright proton craniospinal irradiation

Stéphane Ledot, Zelig Tochner, Aron Popovtzer, Yair Hillman et al.
Clinical and Translational Radiation Oncology
Neuroblastoma Research and Treatments
article

Pediatric CNS relapse of neuroblastoma treated with upright proton craniospinal irradiation

Stéphane Ledot, Zelig Tochner, Aron Popovtzer, Yair Hillman, Alexander Pryanichnikov, Ayman Salhab, Aaron M. Allen, Iris Fried, Philip Blumenfeld, David Gozal, Marc Wygoda, Shimshon Winograd, Sean Marzeeq, Jon Feldmana
article en

Abstract

Craniospinal irradiation (CSI) is a technically demanding treatment in pediatric oncology, especially for young children, who often require daily anesthesia. Although proton therapy offers dosimetric advantages over photons by eliminating exit dose and reducing exposure to healthy tissues, its global availability is limited due to the cost and complexity of gantry-based systems. Recently, gantry-less proton therapy with upright positioning has recently emerged as a compact, cost-efficient alternative, integrating robotic positioning and vertical CT-based image guidance. This study reports the first pediatric case of upright proton CSI delivered under intravenous monitored anesthesia care (MAC) using such a system. A four-year-old male patient with relapsed neuroblastoma in the central nervous system received CSI at a dose of 18.0 Gy(RBE) in 12 fractions, along with a simultaneous integrated boost (SIB) of 21.6 Gy(RBE) to the resection cavity. This was followed by a sequential boost to the resection cavity in five fractions, for a total dose of 30.6 Gy(RBE). The treatment was performed in the seated position with customized immobilization, upright volumetric CT verification, and reproducible daily setup. MAC achieved without intubation, allowing continuous airway access. The patient completed the treatment regimen without interruption, did not experience any grade 2 or higher acute toxicities, and demonstrated adequate tolerance of daily anesthesia. This case demonstrates the clinical feasibility of upright proton CSI under MAC and provides proof of concept for the broader adoption of gantry-less proton therapy in complicated cases.

Clinical and Translational Radiation OncologyVol. 56
Karlsruhe Institute of Technology (DE), German Cancer Research Center (DE), Hebrew University of Jerusalem (IL), Heidelberg University (DE), Hospital of the University of Pennsylvania (US), Hadassah Medical Center (IL), Shaare Zedek Medical Center (IL)
Openalex Percentile: Top 51%
Neuroblastoma Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.