Biomechanical evaluation of femoral neck fracture fixation based on finite element analysis
• The biomechanical performance of all four internal fixation devices (CCS, DHS, DHS+ARS, and FNS) was evaluated. • Pauwels type III at an angle of 70ᴼ fracture was virtually introduced in a femur. • Day-to-day activities of normal walking and stair climbing were simulated. • The stresses, strains, displacements and peri-prosthetic bone adaptations were studied to compare the biomechanical efficacy of such fixation devices. • DHS+ARS seems to be a better-performing system for treating Pauwels type III fracture. Pauwels type III fracture, wherein the fracture plane makes an angle of 50ᴼ-70ᴼ with the transverse plane, is the most unstable femoral neck fracture. Although there are various types of internal fixation devices, including Cannulated cancellous screws (CCS), dynamic hip screw (DHS), dynamic hip screw along with anti-rotation screws (DHS+ARS), and a newly introduced femoral neck system (FNS), patients with Pauwels type III fracture often experience implant failure. There was no study investigating the performance of these internal fixators under physiological musculoskeletal loading. The objective of the present study was to compare the biomechanical performance of CCS, DHS, DHS+ARS, and FNS under daily physiological activities like normal walking and stair climbing. The unstable Pauwels type III fracture was virtually induced in a composite femur bone model and was fixed with all four internal fixators. Second-order tetrahedral elements were used to develop the FE models. The stresses, strains, and deformations of intact and reconstructed femur and implant components were compared to understand the biomechanical efficacy. The periprosthetic long-term bone adaptations for intact and implanted femurs were also studied. FNS showed the highest inferior axial displacement of the femoral head, while DHS+ARS exhibited the least inferior axial displacement. Among the four fracture fixation systems, DHS+ARS offered the highest post-fixation stability in terms of fracture gap opening (normal walking: 0.82mm and stair climbing: 0.95mm) and contact sliding, while the performance of single-hole locking plated FNS was the worst (normal walking: 2.65mm, stair climbing: 3.72mm). DHS+ARS also outperformed other implant systems in terms of long-term bone remodelling. Based on this computational study, DHS+ARS seems to be a better-performing system in Pauwels type III fracture fixation.
Authors
- Samarth Mittal (ORCID: https://orcid.org/0000-0002-2780-1129)
- Apoorva Kabra (ORCID: https://orcid.org/0000-0002-0030-4528)
- Kaushik Mukherjee (ORCID: https://orcid.org/0000-0002-8290-2803)
- Anoop Chawla (ORCID: https://orcid.org/0000-0001-6398-0008)
- Vivek Trikha (ORCID: https://orcid.org/0000-0002-4872-8813)
- L.P. Rao
Institutions
- All India Institute of Medical Sciences (IN)
- Indian Institute of Technology Delhi (IN)
Publication Details
- Journal
- Results in Engineering
- Published
- 2025-11-20
- DOI
- https://doi.org/10.1016/j.rineng.2025.108230
- Primary Topic
- Hip and Femur Fractures
- Type
- article
- Field-Weighted Citation Impact
- 0.00