Experimental and numerical analysis of wet channels for evaporative cooling systems manufactured with polymeric film materials

Evaporative cooling systems have emerged as a sustainable alternative to conventional air-cooling methods, offering reduced energy consumption and environmental impact. This study evaluated the performance of four evaporative cooling channels manufactured using innovative polymeric films with varying porosities and compositions. Material characterization, including microstructure, surface roughness, and water absorption capacities, was systematically performed to identify critical properties affecting evaporative efficiency. Experimental analyses under controlled inlet air conditions identified the channel made of non-woven polypropylene produced by the spunlace technique as exhibiting the highest wet bulb effectiveness (80.6 %). Subsequently, a numerical model based on the effectiveness–number of transfer units ( -NTU) method was developed, validated against experimental results, and utilized to optimize channel geometry and operational conditions. The numerical model indicated that increasing channel length significantly enhances cooling performance up to a saturation point at a channel length-to-free passage area of 1229 m -1 , beyond which further improvements are marginal. These findings provide valuable guidelines for the design and optimization of polymer-based evaporative cooling systems, aiming to balance material properties, geometric factors, and operating conditions for maximum cooling efficiency and sustainability. • Four evaporative cooling channels were manufactured using polymeric materials • A validated ε-NTU-based numerical model was used to optimize channel geometry • Reducing air velocity resulted in a lower outlet air temperature • The maximum wet bulb effectiveness obtained was 80.6% • Optimal cooling was achieved at a L/Ap ratio of 1229 m -1

Authors

Institutions

Publication Details

Journal
Energy
Published
2025-11-20
DOI
https://doi.org/10.1016/j.energy.2025.139370
Citations
2
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and numerical analysis of wet channels for evaporative cooling systems manufactured with polymeric film materials

Francisco Comino, Francisco J. Navas‐Martos, Manuel Ruiz de Adana, Jesús Castillo-González et al.
2 citations
Energy
Adsorption and Cooling Systems
1.43
article

Experimental and numerical analysis of wet channels for evaporative cooling systems manufactured with polymeric film materials

Francisco Comino, Francisco J. Navas‐Martos, Manuel Ruiz de Adana, Jesús Castillo-González, Paula Conrat
article en
2 citations

Abstract

Evaporative cooling systems have emerged as a sustainable alternative to conventional air-cooling methods, offering reduced energy consumption and environmental impact. This study evaluated the performance of four evaporative cooling channels manufactured using innovative polymeric films with varying porosities and compositions. Material characterization, including microstructure, surface roughness, and water absorption capacities, was systematically performed to identify critical properties affecting evaporative efficiency. Experimental analyses under controlled inlet air conditions identified the channel made of non-woven polypropylene produced by the spunlace technique as exhibiting the highest wet bulb effectiveness (80.6 %). Subsequently, a numerical model based on the effectiveness–number of transfer units ( -NTU) method was developed, validated against experimental results, and utilized to optimize channel geometry and operational conditions. The numerical model indicated that increasing channel length significantly enhances cooling performance up to a saturation point at a channel length-to-free passage area of 1229 m -1 , beyond which further improvements are marginal. These findings provide valuable guidelines for the design and optimization of polymer-based evaporative cooling systems, aiming to balance material properties, geometric factors, and operating conditions for maximum cooling efficiency and sustainability. • Four evaporative cooling channels were manufactured using polymeric materials • A validated ε-NTU-based numerical model was used to optimize channel geometry • Reducing air velocity resulted in a lower outlet air temperature • The maximum wet bulb effectiveness obtained was 80.6% • Optimal cooling was achieved at a L/Ap ratio of 1229 m -1

EnergyVol. 340
Centro Tecnológico del Mar (ES), University of Córdoba (ES)
Openalex Percentile: Top 17%
Adsorption and Cooling Systems
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.