First use of computer-generated holography in neuroendovascular simulation and intraoperative assistance: A preliminary study

BackgroundComputer-generated holograms (CGHs) are advanced, glassless, three-dimensional (3D) representations. This study reports the first surgical application of CGH for preoperative and intraoperative assistance.MethodsIn this single-center case series and observational survey study, three consecutive patients with intracranial aneurysms were scheduled for endovascular treatment; in one case, observation was selected instead of treatment. Twelve neurosurgical residents were recruited to inspect the CGHs and complete a questionnaire. CGHs were inspected pre- and intraoperatively in two patients with flow-diverter stents. For validation, neurosurgical residents inspected conventional 3D rotational angiograms, then CGHs, and completed a questionnaire. We compared correct answer rates on a questionnaire assessing 3D anatomical understanding at 10 locations using CGHs versus conventional methods. Simulator Sickness Questionnaire (SSQ) scores were used to assess safety. Outcomes were defined a priori.ResultsCorrect answer rates were higher with CGH than with two-dimensional working angle images (median, 75% vs. 60%; p < .01). Mean SSQ scores were nausea,0.80; oculomotor, 13.9; disorientation, 12.8; and total severity, 10.6. Intraoperative CGH reference particularly assisted the operating surgeon in visualizing and simulating the course of the guidewire across the neck in flow-diverter placement of a giant internal carotid artery aneurysm.ConclusionsThe 3D visualization of anatomical structures in CGH was quantitatively validated in the present study. Comprehension of CGH did not require particular training or prior experience, and its safety profile was also evaluated. CGH may serve as an effective tool for surgical assistance and education, particularly in anatomically complex cases.

Authors

Institutions

Publication Details

Journal
Interventional Neuroradiology
Published
2025-11-20
DOI
https://doi.org/10.1177/15910199251395341
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First use of computer-generated holography in neuroendovascular simulation and intraoperative assistance: A preliminary study

Satoru Miyawaki, Taichi Kin, Hirohito Nishi, Satoshi Kiyofuji et al.
Interventional Neuroradiology
Surgical Simulation and Training
article

First use of computer-generated holography in neuroendovascular simulation and intraoperative assistance: A preliminary study

Satoru Miyawaki, Taichi Kin, Hirohito Nishi, Satoshi Kiyofuji, Kyoji Matsushima, Satoshi Koizumi, Nobuhito Saito
article en

Abstract

BackgroundComputer-generated holograms (CGHs) are advanced, glassless, three-dimensional (3D) representations. This study reports the first surgical application of CGH for preoperative and intraoperative assistance.MethodsIn this single-center case series and observational survey study, three consecutive patients with intracranial aneurysms were scheduled for endovascular treatment; in one case, observation was selected instead of treatment. Twelve neurosurgical residents were recruited to inspect the CGHs and complete a questionnaire. CGHs were inspected pre- and intraoperatively in two patients with flow-diverter stents. For validation, neurosurgical residents inspected conventional 3D rotational angiograms, then CGHs, and completed a questionnaire. We compared correct answer rates on a questionnaire assessing 3D anatomical understanding at 10 locations using CGHs versus conventional methods. Simulator Sickness Questionnaire (SSQ) scores were used to assess safety. Outcomes were defined a priori.ResultsCorrect answer rates were higher with CGH than with two-dimensional working angle images (median, 75% vs. 60%; p < .01). Mean SSQ scores were nausea,0.80; oculomotor, 13.9; disorientation, 12.8; and total severity, 10.6. Intraoperative CGH reference particularly assisted the operating surgeon in visualizing and simulating the course of the guidewire across the neck in flow-diverter placement of a giant internal carotid artery aneurysm.ConclusionsThe 3D visualization of anatomical structures in CGH was quantitatively validated in the present study. Comprehension of CGH did not require particular training or prior experience, and its safety profile was also evaluated. CGH may serve as an effective tool for surgical assistance and education, particularly in anatomically complex cases.

Interventional Neuroradiology
Kansai University (JP), The University of Tokyo (JP)
Openalex Percentile: Top 46%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.