Unified linear-concave transducer enabling 100 Hz plane-wave ultrasound and photoacoustic dynamic imaging

Dual-modal ultrasound (US) and photoacoustic (PA) imaging with linear-array transducers offers clinically relevant imaging depths and flexible access to anatomical sites, while enhancing optical contrast. By integrating anatomical detail from US with the molecular specificity of PA, this approach provides complementary information that supports more accurate and comprehensive diagnostics than either modality alone. Despite its promise, high-quality video-rate dual-modal imaging remains hindered by two longstanding challenges. Conventional linear-array transducers, optimized for US by suppressing grating and side lobes, inherently limit the wide field of view (FOV) and broad fractional bandwidth necessary for effective PA detection. In contrast, concave arrays extend the FOV for PA but introduce substantial grating artifacts in US imaging, compromising structural fidelity. To overcome these constraints, we engineered a unified linear-concave transducer (ULC-T) that enables synchronized video-rate (100 Hz) plane-wave US and multispectral PA imaging on a standard 128-channel acquisition platform. The ULC-T integrates linear and concave segments into a unified array architecture. A spatial correction algorithm compensates for segmentation misalignments, reducing fabrication constraints, while a customized transmit-receive scheme enhances imaging performance. Validated across phantom, small animal, and human studies, the system demonstrates high imaging speed and deep tissue penetration, offering a practical solution to persistent dual-modal integration challenges and showing strong potential for clinical translation.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-11-20
DOI
https://doi.org/10.1364/boe.582030
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unified linear-concave transducer enabling 100 Hz plane-wave ultrasound and photoacoustic dynamic imaging

Yaoyao Cui, Bingqian Yang, Jinyu Yao, Hongyuan Xu et al.
Biomedical Optics Express
Photoacoustic and Ultrasonic Imaging
article

Unified linear-concave transducer enabling 100 Hz plane-wave ultrasound and photoacoustic dynamic imaging

Yaoyao Cui, Bingqian Yang, Jinyu Yao, Hongyuan Xu, Yachao Zhang, Xiao Hu, Song Shen
article en

Abstract

Dual-modal ultrasound (US) and photoacoustic (PA) imaging with linear-array transducers offers clinically relevant imaging depths and flexible access to anatomical sites, while enhancing optical contrast. By integrating anatomical detail from US with the molecular specificity of PA, this approach provides complementary information that supports more accurate and comprehensive diagnostics than either modality alone. Despite its promise, high-quality video-rate dual-modal imaging remains hindered by two longstanding challenges. Conventional linear-array transducers, optimized for US by suppressing grating and side lobes, inherently limit the wide field of view (FOV) and broad fractional bandwidth necessary for effective PA detection. In contrast, concave arrays extend the FOV for PA but introduce substantial grating artifacts in US imaging, compromising structural fidelity. To overcome these constraints, we engineered a unified linear-concave transducer (ULC-T) that enables synchronized video-rate (100 Hz) plane-wave US and multispectral PA imaging on a standard 128-channel acquisition platform. The ULC-T integrates linear and concave segments into a unified array architecture. A spatial correction algorithm compensates for segmentation misalignments, reducing fabrication constraints, while a customized transmit-receive scheme enhances imaging performance. Validated across phantom, small animal, and human studies, the system demonstrates high imaging speed and deep tissue penetration, offering a practical solution to persistent dual-modal integration challenges and showing strong potential for clinical translation.

Biomedical Optics ExpressVol. 16(12)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Suzhou University of Science and Technology (CN), Zhaotong University (CN), Suzhou Institute of Biomedical Engineering and Technology (CN), Comité National de Lutte contre le SIDA (CM), Theranostics (New Zealand) (NZ)
Openalex Percentile: Top 66%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.