Performance evaluation of a geothermal energy wall considering effects of groundwater flow with thermal–hydraulic characteristics of soil

• Neglecting groundwater flow leads to underestimation of EWS thermal performance. • The effect zone differed significantly between the left and right sides of the EWS. • Natural, mixed, and forced convection regimes identified for different flow rates. • Convection enhances EWS heat exchange by 41.5% to 73.1% compared to conduction. • Outlet fluid temperature reduced by 8 °C to 15 °C owing to convection effects. Thermally induced groundwater (GW) flow can significantly influence heat-transfer performance and soil temperature during the operation of an energy wall system (EWS). However, few studies have quantitatively evaluated the influence of thermal convection on EWS performance, particularly with respect to outlet fluid temperature (°C) and heat exchange rate (W). This study investigated the influence of three convection regimes—natural, forced, and mixed—induced by GW flow on the heat-transfer performance of an EWS. A finite element method-based 3D numerical model was employed to simulate the actual dimensions of a subway station constructed in Gwangju, South Korea. The model was validated using an in-situ thermal response test with a steel U-type heat exchanger embedded in a concrete volume of 2 × 3 × 5 m (width × depth × length). The results indicated that natural convection was dominant at GW velocities below 10 −7 m/s, whereas forced convection was dominant at GW velocities above 5 × 10 −6 m/s. Mixed convection (a combination of forced and natural convection) was observed between these ranges. For the summer season (cooling model, where lower outlet fluid temperature indicates improved performance), the thermally induced GW flow resulted in a reduction of the outlet fluid temperature of approximately 8 °C, 11 °C, and 15 °C for natural convection, mixed convection, and forced convection, respectively, compared to that of only conduction heat. Consequently, the heat exchange of the EWS was enhanced by 41.5 %, 56.8 %, and 73.1 %, respectively. These findings suggest that neglecting thermally induced GW flow can lead to a significant underestimation of EWS performance and provide valuable insights for the accurate estimation and design of such systems.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-11-20
DOI
https://doi.org/10.1016/j.applthermaleng.2025.129185
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of a geothermal energy wall considering effects of groundwater flow with thermal–hydraulic characteristics of soil

Ba Huu Dinh, Wonjun Choi, Young-Sang Kim
Applied Thermal Engineering
Geothermal Energy Systems and Applications
article

Performance evaluation of a geothermal energy wall considering effects of groundwater flow with thermal–hydraulic characteristics of soil

Ba Huu Dinh, Wonjun Choi, Young-Sang Kim
article en

Abstract

• Neglecting groundwater flow leads to underestimation of EWS thermal performance. • The effect zone differed significantly between the left and right sides of the EWS. • Natural, mixed, and forced convection regimes identified for different flow rates. • Convection enhances EWS heat exchange by 41.5% to 73.1% compared to conduction. • Outlet fluid temperature reduced by 8 °C to 15 °C owing to convection effects. Thermally induced groundwater (GW) flow can significantly influence heat-transfer performance and soil temperature during the operation of an energy wall system (EWS). However, few studies have quantitatively evaluated the influence of thermal convection on EWS performance, particularly with respect to outlet fluid temperature (°C) and heat exchange rate (W). This study investigated the influence of three convection regimes—natural, forced, and mixed—induced by GW flow on the heat-transfer performance of an EWS. A finite element method-based 3D numerical model was employed to simulate the actual dimensions of a subway station constructed in Gwangju, South Korea. The model was validated using an in-situ thermal response test with a steel U-type heat exchanger embedded in a concrete volume of 2 × 3 × 5 m (width × depth × length). The results indicated that natural convection was dominant at GW velocities below 10 −7 m/s, whereas forced convection was dominant at GW velocities above 5 × 10 −6 m/s. Mixed convection (a combination of forced and natural convection) was observed between these ranges. For the summer season (cooling model, where lower outlet fluid temperature indicates improved performance), the thermally induced GW flow resulted in a reduction of the outlet fluid temperature of approximately 8 °C, 11 °C, and 15 °C for natural convection, mixed convection, and forced convection, respectively, compared to that of only conduction heat. Consequently, the heat exchange of the EWS was enhanced by 41.5 %, 56.8 %, and 73.1 %, respectively. These findings suggest that neglecting thermally induced GW flow can lead to a significant underestimation of EWS performance and provide valuable insights for the accurate estimation and design of such systems.

Applied Thermal EngineeringVol. 284
Chonnam National University (KR)
Openalex Percentile: Top 75%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.