Gentamicin-loaded xerogel coating prevents peri‑prosthetic joint infection in an adult Göttingen minipig model

The risk of infection when inserting orthopedic devices like prostheses, screws, and plates represents a serious and challenging complication in orthopedic surgery. Most infections result from bacterial introduction during surgery, making it crucial and clinically relevant to protect the devices and surrounding tissue with intraoperative antimicrobials, especially in high-risk patients. Therefore, to mitigate this risk, antimicrobial coatings for different types of orthopedic devices have received substantial attention in recent decades with the goal of developing a “self-cleaning” surface. In here, we investigated a new and highly promising coating candidate. The coating was made of a hyperbranched poly(ethylene imine (PEI)) + orthosilicic acid-based hydrogel, that in a sol-gel process was transformed into a solid xerogel, which afterwards was loaded with gentamicin as active compound. The gentamicin-loaded xerogel coating was applied to functional implants i.e., cancellous bone screws, and tested within an advanced minipig model of Staphylococcus aureus induced peri‑prosthetic joint infection, without the use of systemic antimicrobial therapy. The study included evaluation of antimicrobial efficacy (quantification of bacterial load on the screw surface and within the surrounding tissues), pre -and post-insertion characterization of the coating, assessment of local inflammation and gene expression, and acute toxicity. Additionally, the pharmacokinetic in-vivo gentamicin release profile was measured using microdialysis in relevant local compartments. Due to a quick, locally high, and complete gentamicin release, the coating completely eradicated S. aureus from all compartments in all but one minipig. Therefore, this study shows proof of concept for the effectiveness of preventive antimicrobial release-based coatings.

Authors

Institutions

Publication Details

Journal
Materialia
Published
2025-11-20
DOI
https://doi.org/10.1016/j.mtla.2025.102614
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gentamicin-loaded xerogel coating prevents peri‑prosthetic joint infection in an adult Göttingen minipig model

Nicole Lind Henriksen, Ida Clement Thaarup, Thomas Bjarnsholt, Mats Bue et al.
Materialia
Orthopedic Infections and Treatments
article

Gentamicin-loaded xerogel coating prevents peri‑prosthetic joint infection in an adult Göttingen minipig model

Nicole Lind Henriksen, Ida Clement Thaarup, Thomas Bjarnsholt, Mats Bue, Katrine Top Hartmann, Κωνσταντίνος Γιαννακόπουλος, Kerstin Skovgaard, Johanne Gade Lilleøre, Louise Kruse Jensen, Julie Melsted Birch, Andreas Petersen, Henrik Elvang Jensen, M. Vardavoulias, Michael Arkas, Anders Odgaard, Anton Alexander Nolte Peterlin, Marco Bo Hansen, Bent Aalbæk
article en

Abstract

The risk of infection when inserting orthopedic devices like prostheses, screws, and plates represents a serious and challenging complication in orthopedic surgery. Most infections result from bacterial introduction during surgery, making it crucial and clinically relevant to protect the devices and surrounding tissue with intraoperative antimicrobials, especially in high-risk patients. Therefore, to mitigate this risk, antimicrobial coatings for different types of orthopedic devices have received substantial attention in recent decades with the goal of developing a “self-cleaning” surface. In here, we investigated a new and highly promising coating candidate. The coating was made of a hyperbranched poly(ethylene imine (PEI)) + orthosilicic acid-based hydrogel, that in a sol-gel process was transformed into a solid xerogel, which afterwards was loaded with gentamicin as active compound. The gentamicin-loaded xerogel coating was applied to functional implants i.e., cancellous bone screws, and tested within an advanced minipig model of Staphylococcus aureus induced peri‑prosthetic joint infection, without the use of systemic antimicrobial therapy. The study included evaluation of antimicrobial efficacy (quantification of bacterial load on the screw surface and within the surrounding tissues), pre -and post-insertion characterization of the coating, assessment of local inflammation and gene expression, and acute toxicity. Additionally, the pharmacokinetic in-vivo gentamicin release profile was measured using microdialysis in relevant local compartments. Due to a quick, locally high, and complete gentamicin release, the coating completely eradicated S. aureus from all compartments in all but one minipig. Therefore, this study shows proof of concept for the effectiveness of preventive antimicrobial release-based coatings.

MaterialiaVol. 44
Statens Serum Institut (DK), University of Copenhagen (DK), Copenhagen Business School (DK), National Centre of Scientific Research "Demokritos" (GR), Aarhus University (DK), Herlev Hospital (DK), Aarhus University Hospital (DK), Copenhagen University Hospital (DK), Gentofte Hospital (DK), Rigshospitalet (DK), PyroGenesis (Greece) (GR), Technical University of Denmark (DK)
Openalex Percentile: Top 46%
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.