Thermal performance evaluation of a double skin Façade with latticework solar protection: a case study in a humid tropical climate (Panama)

• Thermal performance of latticework in double skin façades under humid tropical climate is analyzed. • Shading without cross ventilation can cause overheating and high thermal inertia. • Latticework alone does not guarantee thermal efficiency in humid tropical climates. • Cross ventilation is crucial to mitigate thermal loads in double skin façades. • An integrated design approach combining shading, materiality, and ventilation is proposed. In light of the growing energy crisis and the need for more sustainable buildings, passive strategies that were once used to improve thermal comfort are reemerging. These strategies reduce dependence on mechanical air conditioning systems. The façades and elements that compose them are among the determining factors in this behavior. This study, conducted at the University of Panama, analyzes the thermal behavior of lattices applied to a perforated double skin façade (DSF) in a humid tropical climate. The study employed a multi-method approach combining experimental measurements, thermographic images, model calibration, and dynamic simulations using DesignBuilder and EnergyPlus. Thermal data were collected over the course of one year using sensors installed on the experimental façade and supplemented with thermography to characterize surface behavior. Nine architectural hypotheses with different lattice configurations, spatial arrangements, and cross ventilation were evaluated. The results showed that incorporating lattices alone does not guarantee adequate thermal performance. Without effective cross ventilation, double skin façades can induce overheating phenomena by increasing solar radiation capture and the accumulation of internal thermal load, generating high thermal inertia with slow dissipation a clearly unfavorable behavior in humid tropical climates, such as in Panama. The study concludes that construction elements such as solar protection latticework should be designed using an integrated approach that considers geometry, material, thickness, orientation, and interaction with natural ventilation in order to optimize thermal performance and reduce dependence on mechanical systems

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-11-20
DOI
https://doi.org/10.1016/j.enbuild.2025.116747
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal performance evaluation of a double skin Façade with latticework solar protection: a case study in a humid tropical climate (Panama)

Oriol París Viviana, M. van den Bosch, Rosnery Castillo
Energy and Buildings
Building Energy and Comfort Optimization
article

Thermal performance evaluation of a double skin Façade with latticework solar protection: a case study in a humid tropical climate (Panama)

Oriol París Viviana, M. van den Bosch, Rosnery Castillo
article en

Abstract

• Thermal performance of latticework in double skin façades under humid tropical climate is analyzed. • Shading without cross ventilation can cause overheating and high thermal inertia. • Latticework alone does not guarantee thermal efficiency in humid tropical climates. • Cross ventilation is crucial to mitigate thermal loads in double skin façades. • An integrated design approach combining shading, materiality, and ventilation is proposed. In light of the growing energy crisis and the need for more sustainable buildings, passive strategies that were once used to improve thermal comfort are reemerging. These strategies reduce dependence on mechanical air conditioning systems. The façades and elements that compose them are among the determining factors in this behavior. This study, conducted at the University of Panama, analyzes the thermal behavior of lattices applied to a perforated double skin façade (DSF) in a humid tropical climate. The study employed a multi-method approach combining experimental measurements, thermographic images, model calibration, and dynamic simulations using DesignBuilder and EnergyPlus. Thermal data were collected over the course of one year using sensors installed on the experimental façade and supplemented with thermography to characterize surface behavior. Nine architectural hypotheses with different lattice configurations, spatial arrangements, and cross ventilation were evaluated. The results showed that incorporating lattices alone does not guarantee adequate thermal performance. Without effective cross ventilation, double skin façades can induce overheating phenomena by increasing solar radiation capture and the accumulation of internal thermal load, generating high thermal inertia with slow dissipation a clearly unfavorable behavior in humid tropical climates, such as in Panama. The study concludes that construction elements such as solar protection latticework should be designed using an integrated approach that considers geometry, material, thickness, orientation, and interaction with natural ventilation in order to optimize thermal performance and reduce dependence on mechanical systems

Energy and BuildingsVol. 351
Universidad de Panamá (PA), Universidad Tecnológica de Panamá (PA), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 62%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.