Towards building energy systems integrating renewable energy sources: A novel entropy-based optimization configuration approach of energy storage

In building energy systems with high renewable energy (RE) penetration, uncertainties from RE intermittency and load stochasticity hinder supply-demand matching. While hybrid energy storage systems (HESSs) offer a viable solution, achieving their full potential requires optimal capacity configuration, a task made particularly complex when integrated with efficiency-sensitive components like heat pumps (HPs). Existing researches often rely on purely economic or technical metrics, lacking a criterion that balances thermodynamic efficiency with cost, while common control strategies frequently overlook the complex operational dynamics of HPs. To address these gaps, this study proposes unit entropy reduction cost, a novel metric integrating thermodynamics and economics, providing the first physically-grounded cost-effectiveness criterion for HESS sizing. Then, advanced HP-aware control strategies are developed that explicitly account for the HP's dynamically varying coefficient of performance (COP) based on operating conditions. Results show thermal storage devices (TSDs) are more cost-efficient per unit entropy reduction, incurring only 30 %–50 % of the cost of electric storage devices (ESDs), while ESDs require only 10 % of TSD capacity for similar entropy reduction. Strategy 2 (ESD-priority) is found to be more suitable for HP-based HESS than Strategy 1 (TSD-priority), and the optimal TSD capacity is identified as 10,000 kWh across different ESD capacities. Finally, a critical HESS synergy failure in HP systems is identified, and an optimized adaptive strategy based on Strategy 2 is proposed and validated, which successfully unlocks the synergistic potential by maintaining HPs in their optimal COP range.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-11-20
DOI
https://doi.org/10.1016/j.csite.2025.107411
Citations
1
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards building energy systems integrating renewable energy sources: A novel entropy-based optimization configuration approach of energy storage

Dongfang Yang, Jun Zhao, Hui Liu, Rui Shen
1 citations
Case Studies in Thermal Engineering
Integrated Energy Systems Optimization
0.73
article

Towards building energy systems integrating renewable energy sources: A novel entropy-based optimization configuration approach of energy storage

Dongfang Yang, Jun Zhao, Hui Liu, Rui Shen
article en
1 citations

Abstract

In building energy systems with high renewable energy (RE) penetration, uncertainties from RE intermittency and load stochasticity hinder supply-demand matching. While hybrid energy storage systems (HESSs) offer a viable solution, achieving their full potential requires optimal capacity configuration, a task made particularly complex when integrated with efficiency-sensitive components like heat pumps (HPs). Existing researches often rely on purely economic or technical metrics, lacking a criterion that balances thermodynamic efficiency with cost, while common control strategies frequently overlook the complex operational dynamics of HPs. To address these gaps, this study proposes unit entropy reduction cost, a novel metric integrating thermodynamics and economics, providing the first physically-grounded cost-effectiveness criterion for HESS sizing. Then, advanced HP-aware control strategies are developed that explicitly account for the HP's dynamically varying coefficient of performance (COP) based on operating conditions. Results show thermal storage devices (TSDs) are more cost-efficient per unit entropy reduction, incurring only 30 %–50 % of the cost of electric storage devices (ESDs), while ESDs require only 10 % of TSD capacity for similar entropy reduction. Strategy 2 (ESD-priority) is found to be more suitable for HP-based HESS than Strategy 1 (TSD-priority), and the optimal TSD capacity is identified as 10,000 kWh across different ESD capacities. Finally, a critical HESS synergy failure in HP systems is identified, and an optimized adaptive strategy based on Strategy 2 is proposed and validated, which successfully unlocks the synergistic potential by maintaining HPs in their optimal COP range.

Case Studies in Thermal EngineeringVol. 76
Tianjin University (CN), Zhejiang University of Water Resource and Electric Power (CN)
Openalex Percentile: Top 21%
Integrated Energy Systems Optimization
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.