Stability Assessment of Unilateral External Fixator Configurations for Open Tibial Fractures: An Experimental Study

The primary objective of external fixation is to stabilize bone fractures, with the mechanical characteristics of the fixation system playing a critical role in shaping the biomechanical environment of the fracture and, consequently, the healing process. This study presents an experimental investigation of the stability of eight unilateral external fixation configurations applied to an open tibial fracture. The stiffness of each configuration was evaluated under axial compression, anterior–posterior (AP) bending, medial–lateral (ML) bending, and torsional loading. In addition, the effects of structural parameters—such as the number of half-pins, planarity of the configuration, and interfragmentary distance—on fixator stiffness and generated stresses were examined. The results revealed a linear relationship between applied load and both bone segment displacement and principal stresses. Biomechanical tests demonstrated that biplanar configurations provide sufficient stability for open tibial fractures, while simultaneously offering an optimal structural design for the fixation system. Moreover, the number of half-pins was identified as a statistically significant factor influencing configuration stiffness under axial loading and torsion, with biplanar configurations proving particularly effective in torsional scenarios. However, in AP and ML bending tests, neither configuration type nor any individual parameter produced statistically significant differences in bending stiffness. Interestingly, interfragmentary distance did not exert a statistically significant effect on configuration stiffness under any loading condition. Furthermore, neither configuration type nor the analyzed parameters had a notable influence on the principal stresses measured at the control points.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-20
DOI
https://doi.org/10.3390/app152212327
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Assessment of Unilateral External Fixator Configurations for Open Tibial Fractures: An Experimental Study

Adil Muminović, Elmedin Mešić, Nedim Pervan, Bakir Muminović et al.
Applied Sciences
Bone fractures and treatments
article

Stability Assessment of Unilateral External Fixator Configurations for Open Tibial Fractures: An Experimental Study

Adil Muminović, Elmedin Mešić, Nedim Pervan, Bakir Muminović, Edvin Rahman
article en

Abstract

The primary objective of external fixation is to stabilize bone fractures, with the mechanical characteristics of the fixation system playing a critical role in shaping the biomechanical environment of the fracture and, consequently, the healing process. This study presents an experimental investigation of the stability of eight unilateral external fixation configurations applied to an open tibial fracture. The stiffness of each configuration was evaluated under axial compression, anterior–posterior (AP) bending, medial–lateral (ML) bending, and torsional loading. In addition, the effects of structural parameters—such as the number of half-pins, planarity of the configuration, and interfragmentary distance—on fixator stiffness and generated stresses were examined. The results revealed a linear relationship between applied load and both bone segment displacement and principal stresses. Biomechanical tests demonstrated that biplanar configurations provide sufficient stability for open tibial fractures, while simultaneously offering an optimal structural design for the fixation system. Moreover, the number of half-pins was identified as a statistically significant factor influencing configuration stiffness under axial loading and torsion, with biplanar configurations proving particularly effective in torsional scenarios. However, in AP and ML bending tests, neither configuration type nor any individual parameter produced statistically significant differences in bending stiffness. Interestingly, interfragmentary distance did not exert a statistically significant effect on configuration stiffness under any loading condition. Furthermore, neither configuration type nor the analyzed parameters had a notable influence on the principal stresses measured at the control points.

Applied SciencesVol. 15(22)
University of Sarajevo (BA)
Federalno Ministarstvo Obrazovanja i Nauke
Openalex Percentile: Top 54%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.