Design and Development of a Compact, Portable Nondispersive Infrared (NDIR)-Based Capnography Device for Real-Time End-Tidal Carbon Dioxide (CO₂) Monitoring

Measuring carbon dioxide (CO₂) in exhaled breath provides critical insight into both ventilation and metabolism. Changes in CO₂ levels can indicate hypoventilation, airway obstruction, circulatory compromise, or metabolic imbalance, allowing the early detection of respiratory distress and other life-threatening conditions. Capnography provides continuous, non-invasive monitoring of respiratory status and metabolic function through the measurement of end-tidal CO₂ (ETCO₂). This work focuses on developing a low-cost, portable, battery-powered capnograph that enables accurate, continuous CO₂ monitoring with minimal discomfort during daily activities. This study presents the design of a portable, battery-powered capnograph for non-invasive monitoring, featuring high measurement precision and a lightweight form factor. The device integrates a rechargeable power system and a Bluetooth wireless interface to enable seamless data transmission to healthcare providers. Signal acquisition and CO₂ concentration estimation are processed in real time using an embedded microcontroller. The prototype successfully performs real-time CO₂ monitoring and wireless data transmission. Based on projected power consumption, the system enables a continuous runtime of up to approximately 22 hours on a 2000 mAh lithium battery, depending on usage conditions. Expected sensing performance follows the SprintIR-6S specifications, supporting measurements up to 20% CO₂ concentration within specified accuracy limits. The compact, portable design supports reliable continuous monitoring and may enhance the early detection of respiratory deterioration in both clinical and emergency settings. By enabling the rapid recognition of changes in ventilatory status, such a system has the potential to improve patient outcomes and expand access to timely respiratory care.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-11-20
DOI
https://doi.org/10.7759/cureus.97324
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Development of a Compact, Portable Nondispersive Infrared (NDIR)-Based Capnography Device for Real-Time End-Tidal Carbon Dioxide (CO₂) Monitoring

Drin Rrmoku
Cureus
Non-Invasive Vital Sign Monitoring
article

Design and Development of a Compact, Portable Nondispersive Infrared (NDIR)-Based Capnography Device for Real-Time End-Tidal Carbon Dioxide (CO₂) Monitoring

Drin Rrmoku
article en

Abstract

Measuring carbon dioxide (CO₂) in exhaled breath provides critical insight into both ventilation and metabolism. Changes in CO₂ levels can indicate hypoventilation, airway obstruction, circulatory compromise, or metabolic imbalance, allowing the early detection of respiratory distress and other life-threatening conditions. Capnography provides continuous, non-invasive monitoring of respiratory status and metabolic function through the measurement of end-tidal CO₂ (ETCO₂). This work focuses on developing a low-cost, portable, battery-powered capnograph that enables accurate, continuous CO₂ monitoring with minimal discomfort during daily activities. This study presents the design of a portable, battery-powered capnograph for non-invasive monitoring, featuring high measurement precision and a lightweight form factor. The device integrates a rechargeable power system and a Bluetooth wireless interface to enable seamless data transmission to healthcare providers. Signal acquisition and CO₂ concentration estimation are processed in real time using an embedded microcontroller. The prototype successfully performs real-time CO₂ monitoring and wireless data transmission. Based on projected power consumption, the system enables a continuous runtime of up to approximately 22 hours on a 2000 mAh lithium battery, depending on usage conditions. Expected sensing performance follows the SprintIR-6S specifications, supporting measurements up to 20% CO₂ concentration within specified accuracy limits. The compact, portable design supports reliable continuous monitoring and may enhance the early detection of respiratory deterioration in both clinical and emergency settings. By enabling the rapid recognition of changes in ventilatory status, such a system has the potential to improve patient outcomes and expand access to timely respiratory care.

CureusVol. 17(11)
University of Prishtina (XK)
Openalex Percentile: Top 66%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.