Intracellular Oxygen Sensors Based on Block Copolymer Micelles Loaded With Phosphorescent Ir( <scp>III</scp> ) and Pt( <scp>II</scp> ) Complexes

ABSTRACT Polymer micelles are established nanocarriers for hydrophobic molecules, but their use as hosts for sensors of physiological parameters remains underexplored. This work investigates the incorporation of phosphorescent transition metal complexes into block copolymer micelles and examines how composition and structure affect micellar stability and photophysical properties. The study also evaluates their potential as a novel class of oxygen nanosensors with lifetime‐based response. Micelles are prepared from block copolymers of poly(ethylene glycol) (PEG) with diverse hydrophobic blocks: polystyrene (PS 35 ‐ b ‐PEG 115 ), poly(methyl methacrylate) (PMMA 55 ‐ b ‐PEG 95 ), polybutadiene (PBd 90 ‐ b ‐PEG 115 ), polydimethylsiloxane (PDMS 15 ‐ b ‐PEG 115 ), and polycaprolactone (PCL 45 ‐ b ‐PEG 115 ). Six phosphorescent complexes, including three Pt(II) and three Ir(III) species, serve as payloads. Screening of “complex@block copolymer” pairs based on sedimentation stability, phosphorescence decay, and oxygen sensitivity identifies Ir3 @PCL 45 ‐ b ‐PEG 115 loaded with 2 wt.% of Ir3 as the optimal biosensing system. For this system, loading efficiency, size distribution, cross‐sensitivity to environmental parameters, Stern–Volmer plots, and MTT cytotoxicity are assessed. Confocal microscopy and phosphorescence lifetime imaging microscopy (PLIM) demonstrate efficient internalization into CHO‐K1 and HeLa cells. The sensor shows distinct lifetime responses under hypoxic, normoxic, and intermediate oxygenation, enabling quantitative intracellular oxygen sensing with pO 2 resolution of 35–40 mm Hg in both cell monolayers and suspensions.

Authors

Institutions

Publication Details

Journal
Journal of Polymer Science
Published
2025-11-20
DOI
https://doi.org/10.1002/pol.20250859
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intracellular Oxygen Sensors Based on Block Copolymer Micelles Loaded With Phosphorescent Ir( III ) and Pt( II ) Complexes

Sergey P. Tunik, Nina A. Zharskaia, Kirill M. Kuznetsov, Anastasia I. Solomatina et al.
1 citations
Journal of Polymer Science
Analytical Chemistry and Sensors
0.74
article

Intracellular Oxygen Sensors Based on Block Copolymer Micelles Loaded With Phosphorescent Ir( III ) and Pt( II ) Complexes

Sergey P. Tunik, Nina A. Zharskaia, Kirill M. Kuznetsov, Anastasia I. Solomatina, Julia R. Shakirova, Ilya S. Kritchenkov, Anastasiia A. Elistratova, Pavel S. Chelushkin
article en
1 citations

Abstract

ABSTRACT Polymer micelles are established nanocarriers for hydrophobic molecules, but their use as hosts for sensors of physiological parameters remains underexplored. This work investigates the incorporation of phosphorescent transition metal complexes into block copolymer micelles and examines how composition and structure affect micellar stability and photophysical properties. The study also evaluates their potential as a novel class of oxygen nanosensors with lifetime‐based response. Micelles are prepared from block copolymers of poly(ethylene glycol) (PEG) with diverse hydrophobic blocks: polystyrene (PS 35 ‐ b ‐PEG 115 ), poly(methyl methacrylate) (PMMA 55 ‐ b ‐PEG 95 ), polybutadiene (PBd 90 ‐ b ‐PEG 115 ), polydimethylsiloxane (PDMS 15 ‐ b ‐PEG 115 ), and polycaprolactone (PCL 45 ‐ b ‐PEG 115 ). Six phosphorescent complexes, including three Pt(II) and three Ir(III) species, serve as payloads. Screening of “complex@block copolymer” pairs based on sedimentation stability, phosphorescence decay, and oxygen sensitivity identifies Ir3 @PCL 45 ‐ b ‐PEG 115 loaded with 2 wt.% of Ir3 as the optimal biosensing system. For this system, loading efficiency, size distribution, cross‐sensitivity to environmental parameters, Stern–Volmer plots, and MTT cytotoxicity are assessed. Confocal microscopy and phosphorescence lifetime imaging microscopy (PLIM) demonstrate efficient internalization into CHO‐K1 and HeLa cells. The sensor shows distinct lifetime responses under hypoxic, normoxic, and intermediate oxygenation, enabling quantitative intracellular oxygen sensing with pO 2 resolution of 35–40 mm Hg in both cell monolayers and suspensions.

Journal of Polymer ScienceVol. 64(3)
St Petersburg University (RU)
Openalex Percentile: Top 24%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.