• A novel method was developed to detect indoor SARS-CoV-2 from air filters. • Ultrasonication and filtration methods had a higher detection ratio of SARS-CoV-2. • SARS-CoV-2 was detected in 100 % of the COVID-19 inpatient rooms. • 1.9–2.9 log copies/day of SARS-CoV-2 were detected in the COVID-19 inpatient rooms. • A positive correlation was observed between inpatient counts and daily viral load. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), can survive in the air for several hours, which poses a risk of airborne transmission and cluster infection, especially in enclosed settings. The recovery of viruses from filters associated with the air purifiers could be an effective means of detecting indoor SARS-CoV-2; however, no standard method has yet been established. This study developed a method to detect indoor SARS-CoV-2 from different types (Types A–C) of air purifiers by elution through ultrasonication, followed by virus concentration, RNA extraction, and reverse transcription quantitative polymerase chain reaction. Among the three virus concentration methods tested, the filtration method demonstrated superior effectiveness. Among 233 filters from three types of air purifiers collected 17 times from each of the 11 locations in a hospital, SARS-CoV-2 RNA was successfully detected from 64 % (11/17) to 100 % (17/17) in samples from all locations, and a higher viral load (mean ± standard deviation, 2.9 ± 0.8 log 10 copies/day) was recovered in the COVID-19 inpatient rooms. The recovered viral load from the Type A and B filters was not positively correlated with the COVID-19 inpatient cases (Pearson’s r = −0.07 and 0.35, respectively), while that from the Type C filter was positively correlated (Pearson’s r = 0.82). This method enables the visualization of SARS-CoV-2 load in each sampling location, thereby helping prevent nosocomial infections and contributing to the potential improvement of public health by facilitating the implementation of appropriate infection control measures.

Authors

Institutions

Publication Details

Journal
Next research.
Published
2025-11-20
DOI
https://doi.org/10.1016/j.nexres.2025.101111
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a novel method to detect indoor SARS-CoV-2 from the dust collection filters of air purifiers

Made Sandhyana Angga, Eiji Haramoto, Soichiro Hirai, Satoru Hosoda
1 citations
Next research.
Infection Control and Ventilation
1.52
article

Development of a novel method to detect indoor SARS-CoV-2 from the dust collection filters of air purifiers

Made Sandhyana Angga, Eiji Haramoto, Soichiro Hirai, Satoru Hosoda
article en
1 citations

Abstract

• A novel method was developed to detect indoor SARS-CoV-2 from air filters. • Ultrasonication and filtration methods had a higher detection ratio of SARS-CoV-2. • SARS-CoV-2 was detected in 100 % of the COVID-19 inpatient rooms. • 1.9–2.9 log copies/day of SARS-CoV-2 were detected in the COVID-19 inpatient rooms. • A positive correlation was observed between inpatient counts and daily viral load. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), can survive in the air for several hours, which poses a risk of airborne transmission and cluster infection, especially in enclosed settings. The recovery of viruses from filters associated with the air purifiers could be an effective means of detecting indoor SARS-CoV-2; however, no standard method has yet been established. This study developed a method to detect indoor SARS-CoV-2 from different types (Types A–C) of air purifiers by elution through ultrasonication, followed by virus concentration, RNA extraction, and reverse transcription quantitative polymerase chain reaction. Among the three virus concentration methods tested, the filtration method demonstrated superior effectiveness. Among 233 filters from three types of air purifiers collected 17 times from each of the 11 locations in a hospital, SARS-CoV-2 RNA was successfully detected from 64 % (11/17) to 100 % (17/17) in samples from all locations, and a higher viral load (mean ± standard deviation, 2.9 ± 0.8 log 10 copies/day) was recovered in the COVID-19 inpatient rooms. The recovered viral load from the Type A and B filters was not positively correlated with the COVID-19 inpatient cases (Pearson’s r = −0.07 and 0.35, respectively), while that from the Type C filter was positively correlated (Pearson’s r = 0.82). This method enables the visualization of SARS-CoV-2 load in each sampling location, thereby helping prevent nosocomial infections and contributing to the potential improvement of public health by facilitating the implementation of appropriate infection control measures.

Next research.Vol. 3
Toho University (JP), Toho University Omori Medical Center (JP), Takeda (Japan) (JP), University of Yamanashi (JP), Teijin (Japan) (JP)
Openalex Percentile: Top 13%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.