PhysioMEA: Signal processing platform for rate and rhythm analysis of multi-electrode array cardiac electrophysiological recordings

Cardiac organoids serve as a valuable model for studying physiological and pathophysiological processes affecting heart rate and rhythm. Multi-electrode arrays (MEA) are widely used for high-throughput electrophysiological assessments. Despite the widespread use of MEA technology in cardiac research, current analysis tools primarily focus on one dimensional (1D) electrophysiological biomarkers and on average interbeat intervals. We aim to develop innovative algorithms to expand cardiac electrophysiological analysis by enabling standardized biomarker calculation, spatiotemporal biomarker dynamics assessment, and comprehensive beat rate variability (BRV) analysis of cardiac organoids. Electrograms were recorded from spontaneously beating cardiac organoids (n = 15), generated from human-induced pluripotent stem cell-derived cardiomyocytes, using 8 × 8 electrode MEA plates. Novel algorithms were developed for R-, S-, and T-peak detection, as well as advanced two dimensions (2D) electrical signal processing of these biomarkers. All algorithms were implemented on the PhysioMEA platform. Biomarker distributions in cardiac organoids exhibited a high degree of similarity in 1D under basal conditions, as indicated by their coefficients of variation (p-value >0.209). In 2D, R- to S-peaks amplitude, maximal slope, peak-to-peak duration and field potential duration coefficients of variation were 39.04 %, 46.95 %, 22.76 %, and 25.00 %, respectively. Additionally, comprehensive analysis of BRV revealed primarily very low frequency content (63.42 %) in cardiac organoid interbeat interval spectra compared to low- and high-frequency components (15.57 % and 21.02 %, respectively). Thus, 1D and 2D electrophysiological analysis and BRV assessment of cardiac organoids using the open-source PhysioMEA platform, shows high similarities in 1D, but not in 2D, between different physiological biomarkers.

Authors

Institutions

Publication Details

Journal
Journal of Molecular and Cellular Cardiology
Published
2025-11-20
DOI
https://doi.org/10.1016/j.yjmcc.2025.11.006
Citations
1
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PhysioMEA: Signal processing platform for rate and rhythm analysis of multi-electrode array cardiac electrophysiological recordings

Alexandra Alexandrovich, Moran Davoodi, Yael Yaniv, Savyon Mazgaoker et al.
1 citations
Journal of Molecular and Cellular Cardiology
Cardiac electrophysiology and arrhythmias
1.39
article

PhysioMEA: Signal processing platform for rate and rhythm analysis of multi-electrode array cardiac electrophysiological recordings

Alexandra Alexandrovich, Moran Davoodi, Yael Yaniv, Savyon Mazgaoker, Ido Weiser-Bitoun, Shani Assayag
article en
1 citations

Abstract

Cardiac organoids serve as a valuable model for studying physiological and pathophysiological processes affecting heart rate and rhythm. Multi-electrode arrays (MEA) are widely used for high-throughput electrophysiological assessments. Despite the widespread use of MEA technology in cardiac research, current analysis tools primarily focus on one dimensional (1D) electrophysiological biomarkers and on average interbeat intervals. We aim to develop innovative algorithms to expand cardiac electrophysiological analysis by enabling standardized biomarker calculation, spatiotemporal biomarker dynamics assessment, and comprehensive beat rate variability (BRV) analysis of cardiac organoids. Electrograms were recorded from spontaneously beating cardiac organoids (n = 15), generated from human-induced pluripotent stem cell-derived cardiomyocytes, using 8 × 8 electrode MEA plates. Novel algorithms were developed for R-, S-, and T-peak detection, as well as advanced two dimensions (2D) electrical signal processing of these biomarkers. All algorithms were implemented on the PhysioMEA platform. Biomarker distributions in cardiac organoids exhibited a high degree of similarity in 1D under basal conditions, as indicated by their coefficients of variation (p-value >0.209). In 2D, R- to S-peaks amplitude, maximal slope, peak-to-peak duration and field potential duration coefficients of variation were 39.04 %, 46.95 %, 22.76 %, and 25.00 %, respectively. Additionally, comprehensive analysis of BRV revealed primarily very low frequency content (63.42 %) in cardiac organoid interbeat interval spectra compared to low- and high-frequency components (15.57 % and 21.02 %, respectively). Thus, 1D and 2D electrophysiological analysis and BRV assessment of cardiac organoids using the open-source PhysioMEA platform, shows high similarities in 1D, but not in 2D, between different physiological biomarkers.

Journal of Molecular and Cellular CardiologyVol. 210
Technion – Israel Institute of Technology (IL), Rambam Health Care Campus (IL)
Openalex Percentile: Top 13%
Cardiac electrophysiology and arrhythmias
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.