LPFG sensor for rapid and accurate in-situ detection of H2O2
To achieve online, rapid, selective, and accurate detection of H 2 O 2 in UV/H 2 O 2 -based photo-oxidative processes for optimizing •OH production, this study developed a long-period fiber grating (LPFG)-based H 2 O 2 sensor using a graphene oxide (GO)-loaded two-line ferrihydrite (2L-Fht) nanozyme. The GO/2L-Fht sensing layer was synthesized via surface precipitation and immobilized onto the grating surface through a combination of chemical bonding and physical adsorption techniques. Acting as a peroxidase-like nanozyme with high enzymatic activity over a wide pH range, 2L-Fht catalyzes the decomposition of H 2 O 2 , releasing water molecules. GO interacts with these water molecules, altering its effective refractive index and inducing a resonance wavelength shift in the LPFG transmission spectrum. The H 2 O 2 concentration was determined by monitoring the wavelength shift. The effects of doping content, coating thickness, and the pH of the solution on sensor performance were investigated. The results demonstrated at a 2L-Fht doping content of 25 wt%, a coating thickness of 958 nm, and a pH of 7.0, the sensor achieved sensitivities of 95.18 and 285 pm/lg( c ) for H 2 O 2 concentration ranges of 10⁻ 8 to 10⁻ 2 M and 0.01 to 1 M, respectively. Additionally, it exhibited a detection limit as low as 3.99 nM and a response time of 6–14 s. The sensor also exhibited high selectivity and repeatability. This study presents the first use of GO/2L-Fht composites for H 2 O 2 sensing, offering an effective approach for rapid and sensitive detection across a pH range of 5–9 and broadening the applications of fiber optic sensing technology. LPFG Sensor for Rapid and Accurate In-Situ Detection of H 2 O 2 • A long-period fiber grating (LPFG)-based H 2 O 2 sensor was developed. • GO/2L-Fht composite sensing layer was created for H 2 O 2 detection. • Working principle of proposed sensor was theoretically analyzed. • Sensitivity, selectivity, repeatability, low limit and pH-range detection were checked. • Sensor showed rapid, selective, and accurate detection of H 2 O 2 over a broad pH range.
Authors
- Zhenting Xie (ORCID: https://orcid.org/0009-0000-2620-5432)
- Nianbing Zhong (ORCID: https://orcid.org/0000-0001-9442-3183)
- Quanhua Xie (ORCID: https://orcid.org/0009-0003-2402-5421)
- Xuefeng He (ORCID: https://orcid.org/0000-0001-7322-5452)
- Wei Fan (ORCID: https://orcid.org/0000-0001-5036-8733)
- Yejun Xiao (ORCID: https://orcid.org/0009-0000-1036-8261)
- Yuanyuan He (ORCID: https://orcid.org/0000-0003-1403-2102)
- Yang Liu (ORCID: https://orcid.org/0009-0003-9380-797X)
- Yuan Zhou (ORCID: https://orcid.org/0009-0008-5367-6270)
- Xiaoyu Zhong
Institutions
- Chongqing Technology and Business University (CN)
- Chongqing University (CN)
- Dalian Institute of Chemical Physics (CN)
- New Mongol Institute of Technology (MN)
- Chongqing University of Technology (CN)
Publication Details
- Journal
- Sensors and Actuators B Chemical
- Published
- 2025-11-11
- DOI
- https://doi.org/10.1016/j.snb.2025.139148
- Primary Topic
- Advanced Nanomaterials in Catalysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00