The Uniaxial Compressive Constitutive Behavior and Mesoscopic Numerical Simulation of HPC Incorporating ASR Mitigation Measures After Ten Years of Alkali Solution Immersion

The salt lake and saline–alkali soil regions of high plateaus are characterized by widespread Alkali–silica reactive (ASR) aggregates, which severely threaten the durability of constructed infrastructure, including railways, highways, and buildings. The research systematically investigates the uniaxial compressive mechanical behavior and stress–strain constitutive relationship of high-performance concrete (HPC) with ASR mitigation measures (performance grades C40, C45, C50, and C60) after ten years of immersion in a standard alkali solution. A corresponding three-dimensional random aggregate mesoscopic concrete model was developed, and mesomechanical numerical simulations were performed to explore the failure process, failure patterns, and underlying mesoscopic damage mechanisms of the specimens. Results show that While the uniaxial compressive strength and elastic modulus of HPC show an expected increase with the concrete strength grade following long-term alkali exposure, both properties demonstrate a clear decline as the equivalent alkali content rises. Comparing and analyzing the C50 specimens of different admixtures, it was found that the air-entraining agent provided the most effective ASR suppression and obtained the highest uniaxial compressive strength compared with the rust inhibitor. By normalizing the stress–strain curves, the long-term constitutive behavior of HPC under alkali corrosion was summarized. Furthermore, mesoscopic model visualizations indicate that cracks initially appear in the mortar and gradually propagate inward during loading, leading to compressive failure characterized by diagonal cracks. Tracking the mesoscopic damage patterns within the specimens demonstrates that microcracks originate in the mortar and progressively extend through aggregates, revealing the underlying micro-damage mechanism. By studying the SEM-EDS images, it is found that HPC with a specific mix ratio designed in this paper can effectively inhibit the ASR effect, and it still has good corrosion resistance in long-term alkali immersion.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-11-20
DOI
https://doi.org/10.3390/buildings15224196
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Uniaxial Compressive Constitutive Behavior and Mesoscopic Numerical Simulation of HPC Incorporating ASR Mitigation Measures After Ten Years of Alkali Solution Immersion

Weiquan Gao, Fan Wang, Weifeng Liu, Juan Guo et al.
Buildings
Concrete and Cement Materials Research
article

The Uniaxial Compressive Constitutive Behavior and Mesoscopic Numerical Simulation of HPC Incorporating ASR Mitigation Measures After Ten Years of Alkali Solution Immersion

Weiquan Gao, Fan Wang, Weifeng Liu, Juan Guo, Hongfa Yu, Jun Yan, Qinghua Tao
article en

Abstract

The salt lake and saline–alkali soil regions of high plateaus are characterized by widespread Alkali–silica reactive (ASR) aggregates, which severely threaten the durability of constructed infrastructure, including railways, highways, and buildings. The research systematically investigates the uniaxial compressive mechanical behavior and stress–strain constitutive relationship of high-performance concrete (HPC) with ASR mitigation measures (performance grades C40, C45, C50, and C60) after ten years of immersion in a standard alkali solution. A corresponding three-dimensional random aggregate mesoscopic concrete model was developed, and mesomechanical numerical simulations were performed to explore the failure process, failure patterns, and underlying mesoscopic damage mechanisms of the specimens. Results show that While the uniaxial compressive strength and elastic modulus of HPC show an expected increase with the concrete strength grade following long-term alkali exposure, both properties demonstrate a clear decline as the equivalent alkali content rises. Comparing and analyzing the C50 specimens of different admixtures, it was found that the air-entraining agent provided the most effective ASR suppression and obtained the highest uniaxial compressive strength compared with the rust inhibitor. By normalizing the stress–strain curves, the long-term constitutive behavior of HPC under alkali corrosion was summarized. Furthermore, mesoscopic model visualizations indicate that cracks initially appear in the mortar and gradually propagate inward during loading, leading to compressive failure characterized by diagonal cracks. Tracking the mesoscopic damage patterns within the specimens demonstrates that microcracks originate in the mortar and progressively extend through aggregates, revealing the underlying micro-damage mechanism. By studying the SEM-EDS images, it is found that HPC with a specific mix ratio designed in this paper can effectively inhibit the ASR effect, and it still has good corrosion resistance in long-term alkali immersion.

BuildingsVol. 15(22)
Urumqi Vocational University (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 63%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines