Effect of 3D printing technology, build orientation, and shell thickness on the accuracy of full-arch dental models for fixed dental prostheses: an in vitro study

The purpose of this study was to assess the effect of 3D printing technology (SLA vs. DLP), print orientation (0°, 10°, 20°), and model shell thickness (2 mm vs. 4 mm) on the manufacturing accuracy of full-arch dental casts with teeth preparations. A reference STL file of a maxillary arch, featuring preparations for a posterior crown and a three-unit bridge, was used to fabricate 144 printed models (72 with SLA and 72 with DLP). Each technology group was subdivided based on print orientation (0°, 10°, 20°) and shell thickness (2 mm, 4 mm), resulting in 12 subgroups with n = 12 each. All models were scanned and analyzed for global and landmark-level deviations using surface superimposition (Geomagic Control X). Trueness was calculated via root mean square (RMS) error, and precision was determined as standard deviation (SD). Data were statistically analyzed using the Kruskal-Wallis test to assess trueness, and precision was evaluated using Levene's median-based test (α = 0.05). Printing technology (DLP vs. SLA), model orientation, and shell thickness showed no significant impact on the overall accuracy, as measured by trueness (RMS: p = 0.453-1.000) and precision (SD: p = 0.117). The overall trueness (RMS) values ranged from 73.9 to 194 µm, with all groups remaining below the clinical acceptability threshold (< 0.2 mm). Isolated significant differences were observed at specific anatomical points but did not impact overall model performance. The type of printing technology, orientation angle, and shell thickness did not significantly affect the global accuracy of full-arch models for fixed prosthodontics.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-20
DOI
https://doi.org/10.1038/s41598-025-24780-4
Citations
2
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
3.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of 3D printing technology, build orientation, and shell thickness on the accuracy of full-arch dental models for fixed dental prostheses: an in vitro study

Ignacio Gil, Seyed Ali Mosaddad, María J. Suárez, Verónica Rodríguez et al.
2 citations
Scientific Reports
Dental materials and restorations
3.35
article

Effect of 3D printing technology, build orientation, and shell thickness on the accuracy of full-arch dental models for fixed dental prostheses: an in vitro study

Ignacio Gil, Seyed Ali Mosaddad, María J. Suárez, Verónica Rodríguez, Jesús Peláez, Celia Tobar Arribas
article en
2 citations

Abstract

The purpose of this study was to assess the effect of 3D printing technology (SLA vs. DLP), print orientation (0°, 10°, 20°), and model shell thickness (2 mm vs. 4 mm) on the manufacturing accuracy of full-arch dental casts with teeth preparations. A reference STL file of a maxillary arch, featuring preparations for a posterior crown and a three-unit bridge, was used to fabricate 144 printed models (72 with SLA and 72 with DLP). Each technology group was subdivided based on print orientation (0°, 10°, 20°) and shell thickness (2 mm, 4 mm), resulting in 12 subgroups with n = 12 each. All models were scanned and analyzed for global and landmark-level deviations using surface superimposition (Geomagic Control X). Trueness was calculated via root mean square (RMS) error, and precision was determined as standard deviation (SD). Data were statistically analyzed using the Kruskal-Wallis test to assess trueness, and precision was evaluated using Levene's median-based test (α = 0.05). Printing technology (DLP vs. SLA), model orientation, and shell thickness showed no significant impact on the overall accuracy, as measured by trueness (RMS: p = 0.453-1.000) and precision (SD: p = 0.117). The overall trueness (RMS) values ranged from 73.9 to 194 µm, with all groups remaining below the clinical acceptability threshold (< 0.2 mm). Isolated significant differences were observed at specific anatomical points but did not impact overall model performance. The type of printing technology, orientation angle, and shell thickness did not significantly affect the global accuracy of full-arch models for fixed prosthodontics.

Scientific ReportsVol. 15(1)
Universidad Complutense de Madrid (ES), Shiraz University of Medical Sciences (IR), Saveetha University (IN)
Universidad Complutense de Madrid
Openalex Percentile: Top 7%
Dental materials and restorations
3.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.