Rapid Arbitrary‐Shape Microscopy of Unsectioned Tissues for Precise Intraoperative Tumor Margin Assessment

Rapid and accurate intraoperative examination of tumor margins is crucial for precise surgical treatment, yet current methods are limited by incomplete tissue sampling and time-consuming sample sectioning. The Rapid Arbitrary-Shape Microscope (RAM) is developed, a bedside imaging system that enables high-speed, 3D microscopy of irregular tissue surfaces without sectioning, providing cellular-resolution images within minutes while preserving tissue morphology post-excision. RAM precisely integrates a 3D scanning module with a robotic platform, seamlessly combining morphological measurements with robotic-driven pathological microscopy. In studies involving metastatic tumors in 39 mouse liver and spleen samples, RAM demonstrated high accuracy in detecting positive margins containing cancer cells, achieving a sensitivity of 99.1% and a specificity of 82.9%. The system's capability is further validated on 12 skin cancer samples from 10 human subjects using nondestructive imaging, highlighting its potential to reduce surgical time and minimize the risk of overlooking residual cancer at surgical margins during intraoperative evaluation.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-11-20
DOI
https://doi.org/10.1002/advs.202511919
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Arbitrary‐Shape Microscopy of Unsectioned Tissues for Precise Intraoperative Tumor Margin Assessment

Li Lin, Hyeon Jeong Lee, Keer Huang, Qing Chen et al.
Advanced Science
Optical measurement and interference techniques
article

Rapid Arbitrary‐Shape Microscopy of Unsectioned Tissues for Precise Intraoperative Tumor Margin Assessment

Li Lin, Hyeon Jeong Lee, Keer Huang, Qing Chen, Peifen Fu, Ying Zheng, Xingyu Jiang, Xiao‐Yong Man, X. Chen, Jun Li, Ying Yue, Hong Zhang, Xiao‐Long Li, Jingyi Feng, Yuexin Lu, Zhicheng Shao, Xiangwei Meng, R. Cai
article en

Abstract

Rapid and accurate intraoperative examination of tumor margins is crucial for precise surgical treatment, yet current methods are limited by incomplete tissue sampling and time-consuming sample sectioning. The Rapid Arbitrary-Shape Microscope (RAM) is developed, a bedside imaging system that enables high-speed, 3D microscopy of irregular tissue surfaces without sectioning, providing cellular-resolution images within minutes while preserving tissue morphology post-excision. RAM precisely integrates a 3D scanning module with a robotic platform, seamlessly combining morphological measurements with robotic-driven pathological microscopy. In studies involving metastatic tumors in 39 mouse liver and spleen samples, RAM demonstrated high accuracy in detecting positive margins containing cancer cells, achieving a sensitivity of 99.1% and a specificity of 82.9%. The system's capability is further validated on 12 skin cancer samples from 10 human subjects using nondestructive imaging, highlighting its potential to reduce surgical time and minimize the risk of overlooking residual cancer at surgical margins during intraoperative evaluation.

Advanced ScienceVol. 13(8)
Second Affiliated Hospital of Zhejiang University (CN), First Affiliated Hospital Zhejiang University (CN), Zhejiang University (CN)
Openalex Percentile: Top 64%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.