Use of the RETeval™ Handheld Electroretinogram Device for Assessing the Risk of Diabetic Retinopathy in Patients With Type 1 Diabetes: A Case Report

Diabetic retinopathy (DR) is the most common and severe ocular complication in diabetes. Significant advances in retinal electrophysiology have emerged in recent years in relation to diabetes-associated eye disease. Growing evidence of neuronal degeneration in DR has been established, most of which comes from electroretinography (ERG) studies. A five-year-old male patient with type 1 diabetes mellitus (T1D), under treatment since 2021, and a 15-year-old male patient with T1D, under treatment since 2019, underwent ERG testing using the RETeval™ device (LKC Technologies, Inc., Germantown, MD, USA) and the DR program. Hemoglobin A1c (HbA1c) levels were measured at regular intervals at the outpatient clinic. The patients obtained DR protocol scores of 21.4 and 26.0, respectively. The median HbA1c during the study period was 6.2% for the first patient and 8.2% for the second. The findings suggest that RETeval could have potential clinical utility in the assessment of visual function and the early detection of diabetic eye changes.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-11-19
DOI
https://doi.org/10.7759/cureus.97206
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of the RETeval™ Handheld Electroretinogram Device for Assessing the Risk of Diabetic Retinopathy in Patients With Type 1 Diabetes: A Case Report

Dorota Pojda‐Wilczek, Sebastian Seget, Sebastian Sirek, Przemysława Jarosz‐Chobot et al.
Cureus
Retinal Diseases and Treatments
article

Use of the RETeval™ Handheld Electroretinogram Device for Assessing the Risk of Diabetic Retinopathy in Patients With Type 1 Diabetes: A Case Report

Dorota Pojda‐Wilczek, Sebastian Seget, Sebastian Sirek, Przemysława Jarosz‐Chobot, Aleksandra Górska, Barbara Trepka-Sirek
article en

Abstract

Diabetic retinopathy (DR) is the most common and severe ocular complication in diabetes. Significant advances in retinal electrophysiology have emerged in recent years in relation to diabetes-associated eye disease. Growing evidence of neuronal degeneration in DR has been established, most of which comes from electroretinography (ERG) studies. A five-year-old male patient with type 1 diabetes mellitus (T1D), under treatment since 2021, and a 15-year-old male patient with T1D, under treatment since 2019, underwent ERG testing using the RETeval™ device (LKC Technologies, Inc., Germantown, MD, USA) and the DR program. Hemoglobin A1c (HbA1c) levels were measured at regular intervals at the outpatient clinic. The patients obtained DR protocol scores of 21.4 and 26.0, respectively. The median HbA1c during the study period was 6.2% for the first patient and 8.2% for the second. The findings suggest that RETeval could have potential clinical utility in the assessment of visual function and the early detection of diabetic eye changes.

CureusVol. 17(11)
Medical University of Silesia (PL)
Openalex Percentile: Top 51%
Retinal Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of the RETeval™ Handheld Electroretinogram Device for Assessing the Risk of Diabetic Retinopathy in Patients With Type 1 Diabetes: A Case Report — Dorota Pojda‐Wilczek, Sebastian Seget, et al. · Cureus (2025) | TGRS Research Map | TGRS