Why study design matters: evaluating bias and generalizability in contrast-enhanced mammography research

We read with great interest the study by Pediconi et al, which evaluated the diagnostic performance of contrastenhanced mammography (CEM) using a highconcentration iodinated contrast medium (HCCM) [1].The study aimed to determine whether a reduced iodine volume-achieved through higher contrast concentration and lower injection volume-could provide a more sustainable alternative to conventional CEM protocols employing lower-concentration contrast media.The authors concluded that reducing the volume of iodinated contrast agent allows for a more sustainable approach to CEM without compromising diagnostic performance.This research question is of considerable importance, as reducing iodine load may benefit both patient safety and ecological impact.However, we believe that the study design imposes important limitations that affect the generalizability of the findings and preclude the definitive conclusions drawn by the authors regarding the applicability of an HCCM protocol.In medical practice, diagnostic testing plays a vital role, and physicians rely on it to refine their clinical assessment.This reliance assumes that the tests yield dependable information about a patient's health status.However,

Authors

Institutions

Publication Details

Journal
Insights into Imaging
Published
2025-11-19
DOI
https://doi.org/10.1186/s13244-025-02139-7
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Why study design matters: evaluating bias and generalizability in contrast-enhanced mammography research

Marc B. I. Lobbes, Patricia J. Nelemans
Insights into Imaging
Digital Radiography and Breast Imaging
article

Why study design matters: evaluating bias and generalizability in contrast-enhanced mammography research

Marc B. I. Lobbes, Patricia J. Nelemans
article en

Abstract

We read with great interest the study by Pediconi et al, which evaluated the diagnostic performance of contrastenhanced mammography (CEM) using a highconcentration iodinated contrast medium (HCCM) [1].The study aimed to determine whether a reduced iodine volume-achieved through higher contrast concentration and lower injection volume-could provide a more sustainable alternative to conventional CEM protocols employing lower-concentration contrast media.The authors concluded that reducing the volume of iodinated contrast agent allows for a more sustainable approach to CEM without compromising diagnostic performance.This research question is of considerable importance, as reducing iodine load may benefit both patient safety and ecological impact.However, we believe that the study design imposes important limitations that affect the generalizability of the findings and preclude the definitive conclusions drawn by the authors regarding the applicability of an HCCM protocol.In medical practice, diagnostic testing plays a vital role, and physicians rely on it to refine their clinical assessment.This reliance assumes that the tests yield dependable information about a patient's health status.However,

Insights into ImagingVol. 16(1)
Maastricht University (NL), Zuyderland Medisch Centrum (NL)
Openalex Percentile: Top 49%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Why study design matters: evaluating bias and generalizability in contrast-enhanced mammography research — Marc B. I. Lobbes, Patricia J. Nelemans · Insights into Imaging (2025) | TGRS Research Map | TGRS