Atrial fibrillation substrate mapping with emphasis on voltage-based guidance

Voltage substrate mapping is a promising tool for the treatment of atrial fibrillation (AF). It is helpful to detect atrial fibrosis, which includes areas with low bipolar voltage, heterogeneous conduction properties, and shortened effective refractory period. The voltage amplitude is typically defined as the maximal peak-to-peak level within a specified time window of interest. Contemporary electroanatomic mapping platforms now enable many thousands of data points to be mapped, so that a geometric model of the atrial endocardium is constructable over a short period of time. This mapping procedure is often done with bipolar electrodes to cancel the far-field signal. The recording site coordinates are projected onto an atrial shell, with interpolation of the voltage data across the shell surface. The amplitude of the recorded bipolar electrogram depicted on the three-dimensional shell provides detailed information for substrate mapping. Wherever there are areas of low peak-to-peak voltage, it is thought to mark the presence of abnormal tissue properties and conduction. However, uncontrolled variables and environmental factors affecting voltage level include the oncoming electrical activation wavefront direction, the catheter incidence angle, the force applied to the catheter, and the region-variable shape and structure of atrial tissue. Techniques and settings to acquire atrial voltage data for AF analysis have not been standardized. Methods to characterize atrial electrograms are also presently limited. These factors affect quality and reproducibility of the mapping results. Herein, voltage substrate mapping and its variables pertaining to AF and radiofrequency ablation are described and discussed, with suggestions for future work efforts.

Authors

Institutions

Publication Details

Journal
World Journal of Cardiology
Published
2025-11-20
DOI
https://doi.org/10.4330/wjc.v17.i11.109739
Citations
1
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Atrial fibrillation substrate mapping with emphasis on voltage-based guidance

Elaine Y. Wan, Deepak Saluja, Henry H. Hsia, Hirad Yarmohammadi et al.
1 citations
World Journal of Cardiology
Atrial Fibrillation Management and Outcomes
1.39
article

Atrial fibrillation substrate mapping with emphasis on voltage-based guidance

Elaine Y. Wan, Deepak Saluja, Henry H. Hsia, Hirad Yarmohammadi, Nicholas S. Peters, Edward J Ciaccio, Angelo Biviano
article en
1 citations

Abstract

Voltage substrate mapping is a promising tool for the treatment of atrial fibrillation (AF). It is helpful to detect atrial fibrosis, which includes areas with low bipolar voltage, heterogeneous conduction properties, and shortened effective refractory period. The voltage amplitude is typically defined as the maximal peak-to-peak level within a specified time window of interest. Contemporary electroanatomic mapping platforms now enable many thousands of data points to be mapped, so that a geometric model of the atrial endocardium is constructable over a short period of time. This mapping procedure is often done with bipolar electrodes to cancel the far-field signal. The recording site coordinates are projected onto an atrial shell, with interpolation of the voltage data across the shell surface. The amplitude of the recorded bipolar electrogram depicted on the three-dimensional shell provides detailed information for substrate mapping. Wherever there are areas of low peak-to-peak voltage, it is thought to mark the presence of abnormal tissue properties and conduction. However, uncontrolled variables and environmental factors affecting voltage level include the oncoming electrical activation wavefront direction, the catheter incidence angle, the force applied to the catheter, and the region-variable shape and structure of atrial tissue. Techniques and settings to acquire atrial voltage data for AF analysis have not been standardized. Methods to characterize atrial electrograms are also presently limited. These factors affect quality and reproducibility of the mapping results. Herein, voltage substrate mapping and its variables pertaining to AF and radiofrequency ablation are described and discussed, with suggestions for future work efforts.

World Journal of CardiologyVol. 17(11)
Columbia University Irving Medical Center (US)
Openalex Percentile: Top 13%
Atrial Fibrillation Management and Outcomes
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.