Fluence Rate Dosimetry for Photodynamic Therapy (PDT)

It has been demonstrated that the fluence rate at the tissue surface may differ significantly from the incident irradiance of light because of multiple scattering and absorption, both of which may vary among patients and tissue types. This AAPM TG report will review the current state-of-the-art fluence rate dosimetry technology. It will describe the two types of detectors currently available for fluence rate measurement, scattering-tip and fluorescence-based detectors, and review their principles of operation. Long term stability the in-air calibration coefficient of isotropic detector has been established to be ±10% using an integrating sphere setup. Various correction factors (medium correction factor beta, backscatter correction factor alpha) was established for common isotropic detectors. The report will recommend strategies to establish calibration and quality assurance procedures for clinical fluence rate dosimetry equipment, and it will establish guidelines for clinical implementation of fluence rate dosimetry.

Authors

Institutions

Publication Details

Journal
Photodiagnosis and Photodynamic Therapy
Published
2025-11-01
DOI
https://doi.org/10.1016/j.pdpdt.2025.104986
Primary Topic
Photodynamic Therapy Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluence Rate Dosimetry for Photodynamic Therapy (PDT)

Timothy C. Zhu, Andreea Dimofte
Photodiagnosis and Photodynamic Therapy
Photodynamic Therapy Research Studies
article

Fluence Rate Dosimetry for Photodynamic Therapy (PDT)

Timothy C. Zhu, Andreea Dimofte
article en

Abstract

It has been demonstrated that the fluence rate at the tissue surface may differ significantly from the incident irradiance of light because of multiple scattering and absorption, both of which may vary among patients and tissue types. This AAPM TG report will review the current state-of-the-art fluence rate dosimetry technology. It will describe the two types of detectors currently available for fluence rate measurement, scattering-tip and fluorescence-based detectors, and review their principles of operation. Long term stability the in-air calibration coefficient of isotropic detector has been established to be ±10% using an integrating sphere setup. Various correction factors (medium correction factor beta, backscatter correction factor alpha) was established for common isotropic detectors. The report will recommend strategies to establish calibration and quality assurance procedures for clinical fluence rate dosimetry equipment, and it will establish guidelines for clinical implementation of fluence rate dosimetry.

Photodiagnosis and Photodynamic TherapyVol. 56
California University of Pennsylvania (US)
Openalex Percentile: Top 50%
Photodynamic Therapy Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.