Development of a MOF‐Based Oxytetracycline‐Selective PVC Membrane Potentiometric Sensor

Abstract Oxytetracycline is widely used in veterinary medicine to protect animals from infections, treat existing conditions, and mitigate stress‐related events such as vaccination, transportation, and medication. However, an overdose of oxytetracycline may lead to several adverse effects, including renal dysfunction, altered mental status, hepatotoxicity, and gastrointestinal disorders. Therefore, accurate determination of oxytetracycline is essential to ensure both therapeutic efficacy and patient safety. In this study, a polyvinyl chloride (PVC) membrane‐based potentiometric sensor selective for oxytetracycline was developed using MIL‐53 (Materials of Institut Lavoisier) as the ionophore. The optimal membrane composition consisted of 3% MIL‐53, 64% nitrophenyloctylether (NPOE), 1% potassium tetrakis(4‐chlorophenyl)borate (KTpClPB), and 32% PVC. The sensor exhibited a linear response in the concentration range of 1.0 × 10 − 2 to 1.0 × 10 − ⁷ M, with a Nernstian slope of 53.1 mV/decade. The pH working range was determined to be 4.56–11.00. It can be concluded that the developed solid contact potentiometric sensor offers satisfactory analytical properties. Analytical application of the sensor was successfully implemented in pharmaceutical formulations, physiological serum, and different water samples.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2025-11-01
DOI
https://doi.org/10.1002/slct.202503389
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a MOF‐Based Oxytetracycline‐Selective PVC Membrane Potentiometric Sensor

Gülşah Saydan Kanberoğlu, Nefel Kaya
2 citations
ChemistrySelect
Analytical Chemistry and Sensors
1.47
article

Development of a MOF‐Based Oxytetracycline‐Selective PVC Membrane Potentiometric Sensor

Gülşah Saydan Kanberoğlu, Nefel Kaya
article en
2 citations

Abstract

Abstract Oxytetracycline is widely used in veterinary medicine to protect animals from infections, treat existing conditions, and mitigate stress‐related events such as vaccination, transportation, and medication. However, an overdose of oxytetracycline may lead to several adverse effects, including renal dysfunction, altered mental status, hepatotoxicity, and gastrointestinal disorders. Therefore, accurate determination of oxytetracycline is essential to ensure both therapeutic efficacy and patient safety. In this study, a polyvinyl chloride (PVC) membrane‐based potentiometric sensor selective for oxytetracycline was developed using MIL‐53 (Materials of Institut Lavoisier) as the ionophore. The optimal membrane composition consisted of 3% MIL‐53, 64% nitrophenyloctylether (NPOE), 1% potassium tetrakis(4‐chlorophenyl)borate (KTpClPB), and 32% PVC. The sensor exhibited a linear response in the concentration range of 1.0 × 10 − 2 to 1.0 × 10 − ⁷ M, with a Nernstian slope of 53.1 mV/decade. The pH working range was determined to be 4.56–11.00. It can be concluded that the developed solid contact potentiometric sensor offers satisfactory analytical properties. Analytical application of the sensor was successfully implemented in pharmaceutical formulations, physiological serum, and different water samples.

ChemistrySelectVol. 10(44)
Van Yüzüncü Yıl Üniversitesi (TR)
Openalex Percentile: Top 15%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.