K-wire Migration Following Acromioclavicular Joint Fixation: A Case Report

Kirschner wire (K-wire) is commonly used for temporary fixation of bone fractures, particularly in pediatric patients, but it poses risks such as breakage and migration. We present the case of a 67-year-old patient who underwent acromioclavicular joint fixation with K-wires after an injury. Nine months post-surgery, a wire fragment was found to have broken and migrated to the neck area. The migration led to the development of a pseudoaneurysm, which required surgical intervention for removal. The wire fragment was successfully removed, and the aneurysm was repaired after rupture. This case highlights the risks associated with wire migration and underscores the importance of strict adherence to the Tension Band Wiring (TBW) technique. Timely removal of fixation devices and regular radiographic monitoring during follow-up are essential to prevent potentially life-threatening complications.

Authors

Institutions

Publication Details

Journal
Ortopedia Traumatologia Rehabilitacja
Published
2025-10-29
DOI
https://doi.org/10.5604/01.3001.0055.4447
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

K-wire Migration Following Acromioclavicular Joint Fixation: A Case Report

Yuliia Filiak, Vadym Sulyma, Liliia V. Tverdokhlib, Roman Bihun et al.
Ortopedia Traumatologia Rehabilitacja
Shoulder and Clavicle Injuries
article

K-wire Migration Following Acromioclavicular Joint Fixation: A Case Report

Yuliia Filiak, Vadym Sulyma, Liliia V. Tverdokhlib, Roman Bihun, Andrii Sribniak, Bohdan Divnych, Myroslav Lehun, Yevhen Nychvyd
article en

Abstract

Kirschner wire (K-wire) is commonly used for temporary fixation of bone fractures, particularly in pediatric patients, but it poses risks such as breakage and migration. We present the case of a 67-year-old patient who underwent acromioclavicular joint fixation with K-wires after an injury. Nine months post-surgery, a wire fragment was found to have broken and migrated to the neck area. The migration led to the development of a pseudoaneurysm, which required surgical intervention for removal. The wire fragment was successfully removed, and the aneurysm was repaired after rupture. This case highlights the risks associated with wire migration and underscores the importance of strict adherence to the Tension Band Wiring (TBW) technique. Timely removal of fixation devices and regular radiographic monitoring during follow-up are essential to prevent potentially life-threatening complications.

Ortopedia Traumatologia RehabilitacjaVol. 27(3)
University of Bern (CH), Ivano-Frankivsk National Medical University (UA), Adal (Poland) (PL), City Clinical Hospital No. 2 (RU)
Openalex Percentile: Top 54%
Shoulder and Clavicle Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

K-wire Migration Following Acromioclavicular Joint Fixation: A Case Report — Yuliia Filiak, Vadym Sulyma, et al. · Ortopedia Traumatologia Rehabilitacja (2025) | TGRS Research Map | TGRS