Ultrasensitive Optical Gas Sensor Based on a Rectangular-like Herriott Cell for Real-Time Atmospheric Methane Detection and Emission Monitoring

Tunable diode laser absorption spectroscopy (TDLAS) provides high sensitivity, superior spectral resolution, and a fast response for quantitative gas analysis across applications such as greenhouse gas monitoring, industrial process control, combustion diagnostics, and respiratory medicine. However, the traditional Herriott multipass cell (MPC)─a key optical component in TDLAS─faces challenges due to its large physical size, low mirror utilization efficiency, and strict alignment requirements, limiting portability and field deployment. In this work, we designed and fabricated a compact rectangular-like Herriott cell (RLHC) with a 12.7 m optical path length and physical dimensions of 9.00 × 6.60 × 3.45 cm<sup>3</sup> (closed-cell volume ∼58.9 mL), representing the smallest MPC reported for a comparable path length. By transforming a circular (24 mm diameter) beam-spot distribution into an elliptical one (24 mm long axis and 6 mm short axis) and folding the optical axis six times using two high-reflectivity plane mirrors, the RLHC achieves a fill factor of 21.9 cm<sup>-2</sup>. Integration of a fiber-coupled collimator and an InGaAs photodetector eliminates the need for active optical alignment, resulting in a self-contained sensing module. Using a 1.65 μm distributed feedback laser, the RLHC-based methane sensor achieves a minimum detection limit (MDL) of 38.93 ppbv and a noise-equivalent absorption coefficient of 1.36 × 10<sup>-5</sup> Hz<sup>-1/2</sup> (approximately an order of magnitude lower than conventional TDLAS systems). Continuous three-day measurements near sewage systems and in ambient air demonstrate strong robustness and long-term stability, underscoring the potential of RLHC-based TDLAS sensors for distributed environmental monitoring, hand-held operation, and large-scale field applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-10
DOI
https://doi.org/10.1021/acs.analchem.5c05600
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Optical Gas Sensor Based on a Rectangular-like Herriott Cell for Real-Time Atmospheric Methane Detection and Emission Monitoring

Yongyong Hu, Lei Dong, Chaofan Feng, Yixin Zhang et al.
1 citations
Analytical Chemistry
Spectroscopy and Laser Applications
0.76
article

Ultrasensitive Optical Gas Sensor Based on a Rectangular-like Herriott Cell for Real-Time Atmospheric Methane Detection and Emission Monitoring

Yongyong Hu, Lei Dong, Chaofan Feng, Yixin Zhang, Gang Wang, Qingyuan Tian, Jialiang Dai, Weidong Chen, Chenglong Wang, Yifan Chen, Hongpeng Wu, Ruyue Cui
article en
1 citations

Abstract

Tunable diode laser absorption spectroscopy (TDLAS) provides high sensitivity, superior spectral resolution, and a fast response for quantitative gas analysis across applications such as greenhouse gas monitoring, industrial process control, combustion diagnostics, and respiratory medicine. However, the traditional Herriott multipass cell (MPC)─a key optical component in TDLAS─faces challenges due to its large physical size, low mirror utilization efficiency, and strict alignment requirements, limiting portability and field deployment. In this work, we designed and fabricated a compact rectangular-like Herriott cell (RLHC) with a 12.7 m optical path length and physical dimensions of 9.00 × 6.60 × 3.45 cm<sup>3</sup> (closed-cell volume ∼58.9 mL), representing the smallest MPC reported for a comparable path length. By transforming a circular (24 mm diameter) beam-spot distribution into an elliptical one (24 mm long axis and 6 mm short axis) and folding the optical axis six times using two high-reflectivity plane mirrors, the RLHC achieves a fill factor of 21.9 cm<sup>-2</sup>. Integration of a fiber-coupled collimator and an InGaAs photodetector eliminates the need for active optical alignment, resulting in a self-contained sensing module. Using a 1.65 μm distributed feedback laser, the RLHC-based methane sensor achieves a minimum detection limit (MDL) of 38.93 ppbv and a noise-equivalent absorption coefficient of 1.36 × 10<sup>-5</sup> Hz<sup>-1/2</sup> (approximately an order of magnitude lower than conventional TDLAS systems). Continuous three-day measurements near sewage systems and in ambient air demonstrate strong robustness and long-term stability, underscoring the potential of RLHC-based TDLAS sensors for distributed environmental monitoring, hand-held operation, and large-scale field applications.

Analytical ChemistryVol. 97(45)
Shanxi University (CN), Université du littoral côte d'opale (FR), Laboratoire de Physico-Chimie de l'Atmosphère (FR), Shanxi University of Traditional Chinese Medicine (CN), Quantum Technologies (Sweden) (SE)
Openalex Percentile: Top 23%
Spectroscopy and Laser Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.