Field construction of novel biopolymer-amended soil-bentonite backfill cutoff wall: Evaluation of in situ stresses, hydraulic conductivity, and chemical compatibility

A novel xanthan gum-soil-bentonite (XG-SB) backfill cutoff wall with a depth of 5 m, length of 10 m, and width of 0.6 m was constructed. For comparison, a conventional soil-bentonite (SB) backfill cutoff wall with identical geometry was also constructed. Three-dimensional earth pressures and pore water pressures within the walls were continuously monitored for 340 d. In situ slug tests and laboratory flexible-wall hydraulic conductivity ( k ) tests were conducted to determine the k of XG-SB and SB backfills. Chemical compatibility was evaluated by using 10.6 mM phenol solution and CaCl 2 (20 mM)-phenol (10.6 mM) mixed solution as permeants in flexible-wall k tests conducted on sampled XG-SB and SB backfill cores. A comprehensive comparison was conducted between the mean in situ effective stresses ( σ ′ m ) and the ratios of flexible wall k to slug test k obtained in this study and those reported in previous studies. A simple equation, developed within the framework of the Kozeny-Carman equation, was proposed to describe the relationship between k and the basic geotechnical parameters of various backfills. The results revealed that the vast majority (95%) of the σ ′ m values ranged from 6 kPa to 14 kPa. Based on the slug tests, the field k value of XG-SB backfill was lower than that of the SB backfill (5.5 × 10 -11 m/s versus 1.1 × 10 -10 m/s). The differences in k values exposure to tap water and CaCl 2 -phenol mixed solution were insignificant for the XG-SB backfill (6.0 × 10 -11 m/s versus 2.1 × 10 -10 m/s). In contrast, a significant difference was observed for the SB backfill (1.6 × 10 -10 m/s versus 1.1 × 10 -9 m/s), highlighting the superior chemical compatibility of XG-SB backfill.

Authors

Institutions

Publication Details

Journal
Journal of Rock Mechanics and Geotechnical Engineering
Published
2025-11-01
DOI
https://doi.org/10.1016/j.jrmge.2025.10.007
Primary Topic
Landfill Environmental Impact Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field construction of novel biopolymer-amended soil-bentonite backfill cutoff wall: Evaluation of in situ stresses, hydraulic conductivity, and chemical compatibility

Krishna R. Reddy, Yan‐Jun Du, Zhe-Yuan Jiang, Xian-Lei Fu et al.
Journal of Rock Mechanics and Geotechnical Engineering
Landfill Environmental Impact Studies
article

Field construction of novel biopolymer-amended soil-bentonite backfill cutoff wall: Evaluation of in situ stresses, hydraulic conductivity, and chemical compatibility

Krishna R. Reddy, Yan‐Jun Du, Zhe-Yuan Jiang, Xian-Lei Fu, Heng Zhuang, Hao Ni, Mei Li, Jingwen Li, Zhongyuan Li, Min Wang
article en

Abstract

A novel xanthan gum-soil-bentonite (XG-SB) backfill cutoff wall with a depth of 5 m, length of 10 m, and width of 0.6 m was constructed. For comparison, a conventional soil-bentonite (SB) backfill cutoff wall with identical geometry was also constructed. Three-dimensional earth pressures and pore water pressures within the walls were continuously monitored for 340 d. In situ slug tests and laboratory flexible-wall hydraulic conductivity ( k ) tests were conducted to determine the k of XG-SB and SB backfills. Chemical compatibility was evaluated by using 10.6 mM phenol solution and CaCl 2 (20 mM)-phenol (10.6 mM) mixed solution as permeants in flexible-wall k tests conducted on sampled XG-SB and SB backfill cores. A comprehensive comparison was conducted between the mean in situ effective stresses ( σ ′ m ) and the ratios of flexible wall k to slug test k obtained in this study and those reported in previous studies. A simple equation, developed within the framework of the Kozeny-Carman equation, was proposed to describe the relationship between k and the basic geotechnical parameters of various backfills. The results revealed that the vast majority (95%) of the σ ′ m values ranged from 6 kPa to 14 kPa. Based on the slug tests, the field k value of XG-SB backfill was lower than that of the SB backfill (5.5 × 10 -11 m/s versus 1.1 × 10 -10 m/s). The differences in k values exposure to tap water and CaCl 2 -phenol mixed solution were insignificant for the XG-SB backfill (6.0 × 10 -11 m/s versus 2.1 × 10 -10 m/s). In contrast, a significant difference was observed for the SB backfill (1.6 × 10 -10 m/s versus 1.1 × 10 -9 m/s), highlighting the superior chemical compatibility of XG-SB backfill.

Journal of Rock Mechanics and Geotechnical Engineering
Ministry of Ecology and Environment (CN), University of Illinois Chicago (US), Annoroad Gene Technology (China) (CN), China Construction Eighth Engineering Division (China) (CN), Nanjing Institute of Environmental Sciences (CN), Southeast University (CN)
Openalex Percentile: Top 58%
Landfill Environmental Impact Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.