A Nested DUAL-axis Accelerometer with Enhanced Temperature Robustness for Testing Across the Entire Operational Temperature Range

Abstract This paper investigates a nested biaxial micro-electro-mechanical systems (MEMS) accelerometer with low coupling error, derives the kinetic model equations of the accelerometer, and performs finite element simulations of the operating modes and mechanical coupling of the structure. The accelerometer uses an inner and outer nested structure with non-rigid links to reduce cross-coupling between orthogonal sensitive axes. Closed-loop control is employed to further improve the device stability and reduce the coupling coefficient. The preparation and testing of the structure was finally completed. Without compensation, tests show that the accelerometer works in closed-loop mode with low cross-coupling, and the inter-axis cross-coupling coefficients are less than 1.31 % and 2.4 %, respectively. The accelerometer exhibits an X-axis output drift of 1.26 mg/°C and a Y-axis output drift of 0.91 mg/°C in its natural state over the full temperature range of −40 °C to 60 °C. After compensation by the temperature compensation system, the X-axis output bias is optimized to 0.02008 mg/°C and the Y-axis output bias to 0.02041 mg/°C.

Authors

Institutions

Publication Details

Journal
Measurement Science Review
Published
2025-11-13
DOI
https://doi.org/10.2478/mr-2025-0035
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Nested DUAL-axis Accelerometer with Enhanced Temperature Robustness for Testing Across the Entire Operational Temperature Range

Xiao Hu, Yanchao Ren, Jingjing Jiao, Guodong Duan
Measurement Science Review
Advanced MEMS and NEMS Technologies
article

A Nested DUAL-axis Accelerometer with Enhanced Temperature Robustness for Testing Across the Entire Operational Temperature Range

Xiao Hu, Yanchao Ren, Jingjing Jiao, Guodong Duan
article en

Abstract

Abstract This paper investigates a nested biaxial micro-electro-mechanical systems (MEMS) accelerometer with low coupling error, derives the kinetic model equations of the accelerometer, and performs finite element simulations of the operating modes and mechanical coupling of the structure. The accelerometer uses an inner and outer nested structure with non-rigid links to reduce cross-coupling between orthogonal sensitive axes. Closed-loop control is employed to further improve the device stability and reduce the coupling coefficient. The preparation and testing of the structure was finally completed. Without compensation, tests show that the accelerometer works in closed-loop mode with low cross-coupling, and the inter-axis cross-coupling coefficients are less than 1.31 % and 2.4 %, respectively. The accelerometer exhibits an X-axis output drift of 1.26 mg/°C and a Y-axis output drift of 0.91 mg/°C in its natural state over the full temperature range of −40 °C to 60 °C. After compensation by the temperature compensation system, the X-axis output bias is optimized to 0.02008 mg/°C and the Y-axis output bias to 0.02041 mg/°C.

Measurement Science ReviewVol. 25(6)
Vanguard University (US), National University of Defense Technology (CN)
National University of Defense Technology
Openalex Percentile: Top 66%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.