Numerical and Experimental Study on the Effect of External Box Stiffeners for Rigid Connections of I-Beams to Concrete-Filled Circular Columns

This study introduces an innovative connection to improve the seismic performance of I-beam–to–concrete-filled circular column joints. The concept employs a steel box with optimized internal and external stiffeners, eliminating continuity and doubler plates to simplify construction. Calibrated finite-element analyses were first conducted to select three configurations for experimental testing under cyclic quasi-static loading, measuring energy dissipation, stiffness, ultimate moment, panel-zone rotation, and strain distribution. The best-performing specimen was then identified, followed by a numerical parametric study varying beam and column dimensions to determine the minimum steel-box thickness beyond which further increases offer negligible benefit and to assess its effect on connection rigidity. Experimentally, stiffeners aligned with beam flanges significantly improved moment capacity, stiffness, and energy dissipation. Based on parametric analyses, connections with appropriate box-to-flange thickness ratios achieved over 95% of the maximum flexural strength and stiffness, confirming the reliability of the proposed non-dimensional design approach. Numerical analyses showed that the proposed non-dimensional thickness ratios accurately predict connection behavior, where appropriate flange-to-box proportions ensure over 95% of maximum flexural strength and stiffness, leading to stable and rigid joint performance. Overall, the proposed detailing offers a constructible alternative to conventional plate-intensive solutions while achieving superior cyclic behavior.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-11-14
DOI
https://doi.org/10.3390/buildings15224116
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and Experimental Study on the Effect of External Box Stiffeners for Rigid Connections of I-Beams to Concrete-Filled Circular Columns

AllahReza Moradi Garoosi, Javad Esfandiari, Ary Shehab Jamil, Mehrzad TahamouliRoudsari
1 citations
Buildings
Structural Load-Bearing Analysis
0.95
article

Numerical and Experimental Study on the Effect of External Box Stiffeners for Rigid Connections of I-Beams to Concrete-Filled Circular Columns

AllahReza Moradi Garoosi, Javad Esfandiari, Ary Shehab Jamil, Mehrzad TahamouliRoudsari
article en
1 citations

Abstract

This study introduces an innovative connection to improve the seismic performance of I-beam–to–concrete-filled circular column joints. The concept employs a steel box with optimized internal and external stiffeners, eliminating continuity and doubler plates to simplify construction. Calibrated finite-element analyses were first conducted to select three configurations for experimental testing under cyclic quasi-static loading, measuring energy dissipation, stiffness, ultimate moment, panel-zone rotation, and strain distribution. The best-performing specimen was then identified, followed by a numerical parametric study varying beam and column dimensions to determine the minimum steel-box thickness beyond which further increases offer negligible benefit and to assess its effect on connection rigidity. Experimentally, stiffeners aligned with beam flanges significantly improved moment capacity, stiffness, and energy dissipation. Based on parametric analyses, connections with appropriate box-to-flange thickness ratios achieved over 95% of the maximum flexural strength and stiffness, confirming the reliability of the proposed non-dimensional design approach. Numerical analyses showed that the proposed non-dimensional thickness ratios accurately predict connection behavior, where appropriate flange-to-box proportions ensure over 95% of maximum flexural strength and stiffness, leading to stable and rigid joint performance. Overall, the proposed detailing offers a constructible alternative to conventional plate-intensive solutions while achieving superior cyclic behavior.

BuildingsVol. 15(22)
Islamic Azad University Sanandaj Branch (IR), Islamic Azad University of Kermanshah (IR), Islamic Azad University Kerman (IR)
Openalex Percentile: Top 20%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.