ANATOMICAL EVALUATION OF OPTIMAL PLATE POSITIONING FOR DISTAL FEMUR LOCKING COMPRESSION PLATES: A CADAVERIC STUDY IN THE INDIAN POPULATION

Background: Anatomically pre-contoured distal femur locking compression plates (DF-LCP) are based on Western morphometric data and may not fit Indian femora accurately, risking intra-articular screw penetration or posterior cruciate ligament (PCL) impingement. To identify Objective: the optimal DF-LCP position using consistent bony landmarks in Indian femora. Forty-eight adult cada Methods: veric femora were studied. DFLCPs from three manufacturers were applied at four positions relative to the lateral epicondyle—S3 (3 mm superior), I3 (3 mm inferior), 0 (neutral), and A3 (3 mm anterior). Radiographic and clinical assessments, including notch-view imaging, evaluated screw penetration and PCL proximity. Overall screw penetration was 54.2 %. The S3 position had 0 % penetration, while I3 had 1 Results: 00 %. Shorter femora (36 ± 3 cm) showed more penetration than longer ones (42 ± 3 cm). Placing the DF-LCP about 3 mm proximal to the Conclusion: lateral epicondyle (S3 position) minimizes joint and PCL violation. Intra-operative notch-view verification and plate designs based on Indian morphology are recommended.

Authors

Institutions

Publication Details

Journal
INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH
Published
2025-11-01
DOI
https://doi.org/10.36106/ijsr/0205004
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANATOMICAL EVALUATION OF OPTIMAL PLATE POSITIONING FOR DISTAL FEMUR LOCKING COMPRESSION PLATES: A CADAVERIC STUDY IN THE INDIAN POPULATION

Elangovan Srinivas, Mohan Ganesan, Buvanesh Janakiraman
INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH
Knee injuries and reconstruction techniques
article

ANATOMICAL EVALUATION OF OPTIMAL PLATE POSITIONING FOR DISTAL FEMUR LOCKING COMPRESSION PLATES: A CADAVERIC STUDY IN THE INDIAN POPULATION

Elangovan Srinivas, Mohan Ganesan, Buvanesh Janakiraman
article en

Abstract

Background: Anatomically pre-contoured distal femur locking compression plates (DF-LCP) are based on Western morphometric data and may not fit Indian femora accurately, risking intra-articular screw penetration or posterior cruciate ligament (PCL) impingement. To identify Objective: the optimal DF-LCP position using consistent bony landmarks in Indian femora. Forty-eight adult cada Methods: veric femora were studied. DFLCPs from three manufacturers were applied at four positions relative to the lateral epicondyle—S3 (3 mm superior), I3 (3 mm inferior), 0 (neutral), and A3 (3 mm anterior). Radiographic and clinical assessments, including notch-view imaging, evaluated screw penetration and PCL proximity. Overall screw penetration was 54.2 %. The S3 position had 0 % penetration, while I3 had 1 Results: 00 %. Shorter femora (36 ± 3 cm) showed more penetration than longer ones (42 ± 3 cm). Placing the DF-LCP about 3 mm proximal to the Conclusion: lateral epicondyle (S3 position) minimizes joint and PCL violation. Intra-operative notch-view verification and plate designs based on Indian morphology are recommended.

INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH
ACS Medical College and Hospital (IN), Orthopaedic Research Group (IN), Bharath University (IN)
Openalex Percentile: Top 46%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.