Full dynamic simulation of an adiabatic compressed air energy storage plant with radial-flow packed-bed storage and an organic Rankine cycle unit

[EN]This work analyzes several adiabatic compressed air energy systems (ACAES) configurations with a thermodynamic time-dependent model. ACAES systems allow for large-scale energy storage, with fast response times and high output power. However, despite being a promising technology, few works have been done in systematically modeling the unsteady dynamic operation and integrating all components in ACAES plants. The developed model in this work can simulate the thermodynamic behavior of the plant components individually and their integration into an ACAES plant as a whole. The influence of an additional organic Rankine cycle on the round-trip efficiency of the plant is also studied. A comparison of the performance of several plant arrangements is obtained under a unified framework, filling an observed gap in the reported literature. Particular results include the centrifugal compression train working along the peak-line efficiency, the analysis and comparison of pressure drops in packed-bed subsystems used as thermal energy storage: axial or radial, and the optimization of the inlet pressure in the Rankine evaporator. As a conclusion, pressure drops in the radial packed-beds are found to be about 20% lower than in axial packed-beds, and global round-trip efficiencies can be improved by about 2%?3% (reaching values of 0.78) by selecting a suitable symmetrical configuration or by coupling a Rankine cycle. This increase in efficiency is due to the notable reduction in destroyed exergy when an optimized organic Rankine is used for heat recovery instead of discharging heat by an intercooler device.

Authors

Publication Details

Journal
Energy Conversion and Management
Published
2025-11-16
DOI
https://doi.org/10.1016/j.enconman.2025.120764
Citations
1
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full dynamic simulation of an adiabatic compressed air energy storage plant with radial-flow packed-bed storage and an organic Rankine cycle unit

Ignacio Calderón-Vásquez, A. Calvo Hernández, David Pérez-Gallego, Julián González-Ayala et al.
1 citations
Energy Conversion and Management
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.71
article

Full dynamic simulation of an adiabatic compressed air energy storage plant with radial-flow packed-bed storage and an organic Rankine cycle unit

Ignacio Calderón-Vásquez, A. Calvo Hernández, David Pérez-Gallego, Julián González-Ayala, A. Medina
article en
1 citations

Abstract

[EN]This work analyzes several adiabatic compressed air energy systems (ACAES) configurations with a thermodynamic time-dependent model. ACAES systems allow for large-scale energy storage, with fast response times and high output power. However, despite being a promising technology, few works have been done in systematically modeling the unsteady dynamic operation and integrating all components in ACAES plants. The developed model in this work can simulate the thermodynamic behavior of the plant components individually and their integration into an ACAES plant as a whole. The influence of an additional organic Rankine cycle on the round-trip efficiency of the plant is also studied. A comparison of the performance of several plant arrangements is obtained under a unified framework, filling an observed gap in the reported literature. Particular results include the centrifugal compression train working along the peak-line efficiency, the analysis and comparison of pressure drops in packed-bed subsystems used as thermal energy storage: axial or radial, and the optimization of the inlet pressure in the Rankine evaporator. As a conclusion, pressure drops in the radial packed-beds are found to be about 20% lower than in axial packed-beds, and global round-trip efficiencies can be improved by about 2%?3% (reaching values of 0.78) by selecting a suitable symmetrical configuration or by coupling a Rankine cycle. This increase in efficiency is due to the notable reduction in destroyed exergy when an optimized organic Rankine is used for heat recovery instead of discharging heat by an intercooler device.

Energy Conversion and ManagementVol. 348
Openalex Percentile: Top 25%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.