A compact SNG-SRR Metamaterial sensor with enhanced sensitivity for biomedical applications

This paper presents a compact single-negative (SNG) split-ring resonator (SRR) metamaterial sensor developed for non-invasive wound dressing moisture monitoring. The sensor is fabricated on a Rogers RT5880 substrate ( ɛ r = 2 . 2 , tan δ = 0 . 009 ), occupies only 25 × 20 mm 2 , and operates reliably within the 2.0–2.8 GHz band, exhibiting a sharp − 28 dB transmission notch at 2.43 GHz. By exploiting epsilon-negative (ENG, ɛ < 0 ) behavior, the design achieves strong electromagnetic field confinement and a high surface current density of 98.8 A/m, enabling superior sensitivity and resonance selectivity compared to conventional SRR/CSRR sensors. The sensor’s performance was validated through both simulations and experiments using five wound dressing materials: (i) cotton gauze, (ii) hydrocolloid, (iii) polyurethane, (iv) alginate, and (v) hydrogel, under dry and soaked conditions. As the effective permittivity increased from ɛ r = 2 . 2 (dry) to ɛ r = 18 . 0 (20% blood concentration), the resonance frequency shifted from 2.43 GHz to 1.70 GHz, corresponding to a total shift of 0.73 GHz. This yielded normalized sensitivities ranging from 10.3% at 5% blood concentration to 30.0% at 20% blood concentration, with slope-based sensitivity peaking at 4.1% / ɛ near 10% blood concentration. Importantly, the sensor maintained a Q-factor above 30 across all loading conditions, confirming its robustness and measurement reliability. Operating within the 2.0–2.8 GHz range, the proposed sensor offers high sensitivity, stability, and ease of integration. This breakthrough SRR design demonstrates strong potential for enhancing wound management by enabling efficient, real-time, and precise moisture monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Science Advanced Materials and Devices
Published
2025-11-11
DOI
https://doi.org/10.1016/j.jsamd.2025.101044
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A compact SNG-SRR Metamaterial sensor with enhanced sensitivity for biomedical applications

Mohamed S. Soliman, Yazeed Alkhrijah, Mohd Hafiz Baharuddin, Abdulmajeed M. Alenezi et al.
Journal of Science Advanced Materials and Devices
Microwave and Dielectric Measurement Techniques
article

A compact SNG-SRR Metamaterial sensor with enhanced sensitivity for biomedical applications

Mohamed S. Soliman, Yazeed Alkhrijah, Mohd Hafiz Baharuddin, Abdulmajeed M. Alenezi, Md. Shakhawat Hossen, Mohamad A. Alawad, Mohammad Tariqul Islam, Mohamed Ouda
article en

Abstract

This paper presents a compact single-negative (SNG) split-ring resonator (SRR) metamaterial sensor developed for non-invasive wound dressing moisture monitoring. The sensor is fabricated on a Rogers RT5880 substrate ( ɛ r = 2 . 2 , tan δ = 0 . 009 ), occupies only 25 × 20 mm 2 , and operates reliably within the 2.0–2.8 GHz band, exhibiting a sharp − 28 dB transmission notch at 2.43 GHz. By exploiting epsilon-negative (ENG, ɛ < 0 ) behavior, the design achieves strong electromagnetic field confinement and a high surface current density of 98.8 A/m, enabling superior sensitivity and resonance selectivity compared to conventional SRR/CSRR sensors. The sensor’s performance was validated through both simulations and experiments using five wound dressing materials: (i) cotton gauze, (ii) hydrocolloid, (iii) polyurethane, (iv) alginate, and (v) hydrogel, under dry and soaked conditions. As the effective permittivity increased from ɛ r = 2 . 2 (dry) to ɛ r = 18 . 0 (20% blood concentration), the resonance frequency shifted from 2.43 GHz to 1.70 GHz, corresponding to a total shift of 0.73 GHz. This yielded normalized sensitivities ranging from 10.3% at 5% blood concentration to 30.0% at 20% blood concentration, with slope-based sensitivity peaking at 4.1% / ɛ near 10% blood concentration. Importantly, the sensor maintained a Q-factor above 30 across all loading conditions, confirming its robustness and measurement reliability. Operating within the 2.0–2.8 GHz range, the proposed sensor offers high sensitivity, stability, and ease of integration. This breakthrough SRR design demonstrates strong potential for enhancing wound management by enabling efficient, real-time, and precise moisture monitoring.

Journal of Science Advanced Materials and DevicesVol. 10(4)
Taif University (SA), Imam Mohammad ibn Saud Islamic University (SA), Islamic University (BD), Qatar Science and Technology Park (QA), Islamic University of Madinah (SA), National University of Malaysia (MY)
Openalex Percentile: Top 66%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.